ActiveSources Sought
Save

Supreme Court Building Fire Alarm System Upgrade

Architect of the Capitol > MATERIAL MAN DIV
TBD
est. $250K – $750K

This is a Sources Sought notice

The agency is researching potential vendors before issuing a formal solicitation. Responding shows your capabilities and can influence the final RFP.

Quick Brief

The Architect of the Capitol is procuring an upgrade of the fire alarm system for the Supreme Court of the United States. The project requires replacing the obsolete Edwards EST-3 system with a fully operational Edwards EST-4 system to ensure code compliance and long-term reliability. Key requirements include the procurement, installation, and programming of control panels, power supplies, and the integration of the FireWorks graphical monitoring system.

Generated 14d ago

Can you respond to this?

Get your fit score, win probability, and required capabilities.

Fit Score7/10Consider

Scope & Requirements

Upgrade the existing Edwards EST-3 fire alarm system to an Edwards EST-4 system, including installation of control panels, power supplies, and integration of FireWorks graphical monitoring.

Deliverables

  • Installed and programmed EST-4 fire alarm system
  • Updated/replaced annunciator panels
  • Integrated FireWorks graphical monitoring system
  • System acceptance testing reports

Contract Details

Contract Type
TBD
Estimated Value
est. $250K – $750K
Similar contracts award $13K to $139K (median $39K, 9,267 awards)Above typical range
Period of Performance
one-year base
NAICS Codes

Agency & Contact

Contracting Organization

Agency
ARCHITECT OF THE CAPITOL
Office
MATERIAL MAN DIV

Point of Contact

John A. Smith
Contracting Officer
(202) 555-0100

Key Dates

Published15d ago
Jul 10, 2026
Last Updated15d ago
Jul 10, 2026
Became Solicitation14d ago
Jul 10, 2026
Tracked
Response Dateyesterday
Jul 24, 202612:00 PM EDT
Response Duein 20d
Aug 14, 2026

Description

The Supreme Court of the United States has a requirement for a contract for Supreme Court Building with a

period of performance of a one-year base. PROJECT TITLE Fire Alarm System Upgrade, SCBG

Background Established as a permanent , the Architect is provided permanent authority for the care and maintenance of the United States Capitol based on Section 1811 of Title 2 of the United States Code. The Architect is responsible for the maintenance, operation, development and preservation of 18.4 million square feet of buildings and more than 580 acres of land throughout Capitol Hill. This includes the U.S. Capitol, House and Senate , the U.S. Capitol Visitor Center, the Library of Congress, the Supreme Court of the United States (SCOTUS), the U.S. Botanic Garden, the Capitol Power Plant, and other facilities. The Architect also provides professional expertise with regard to the preservation of architectural and artistic elements entrusted to his care and provides recommendations concerning design, construction and maintenance of the facilities and grounds. The SCOTUS’s existing fire alarm system is an Edwards EST-3 system that has reached the later stages of its service life. The system has two annunciators as well as two FireWorks stations. The EST-3 platform is no longer actively supported to the same extent as newer systems, and replacement parts, software support, and qualified service availability are becoming increasingly limited. For example, one of the existing fire alarm annunciator screens is non‑functional and no longer supported by the manufacturer. Replacement parts are no longer available. To maintain a reliable, code-compliant life safety system and to support long-term operational needs, an upgrade to the Edwards EST-4 fire alarm system is required. The EST-4 platform provides enhanced processing capability, improved system diagnostics, expanded networking and integration options, and ongoing manufacturer support. Upgrading to the EST-4 system will improve overall system performance, ensure continued compliance with applicable codes and standards, and provide a sustainable solution for future facility

requirements.

Scope of Work The Contractor shall provide all labor, materials, equipment, tools, supervision, and services necessary to upgrade the existing Edwards EST-3 fire alarm system to a fully operational Edwards EST-4 fire alarm system. The work shall include, but is not limited to, furnishing, delivering, installing, programming, testing, and placing into service a complete EST-4 system that complies with all applicable codes, standards, and manufacturer

requirements. The

Get matched to contracts like this daily