Building 1 HVAC Repair at Blue Ash ANGB

Department of Defense (DoD) > U.S. Army > JFHQ USPFO OH
$13K – $126K per task order

This opportunity is closed

The response deadline has passed. Review the details for future reference or to track similar opportunities.

Quick Brief

The project involves repairing the HVAC system at Building 1 of the Blue Ash Air National Guard Base. Key requirements include removing and disposing of the existing 30-ton rooftop unit, installing a new unit, and updating controls and components associated with the HVAC system.

Generated 61d ago

Scope & Requirements

The work includes the removal of the existing HVAC rooftop unit, installation of a new unit, and updates to the HVAC controls and components.

Contract Details

Contract Value
$13K – $126K per task order
IDIQ ceiling: $19M
Similar contracts award $13K$126K (median $35K, 14,862 awards)
Estimated value range
NAICS Codes
Place of Performance
Blue Ash

Qualifications & Eligibility

NAICS Size Standard
$19,000,000.00

Agency & Contact

Contracting Organization

Agency
DEPT OF DEFENSE
Sub-Agency
DEPT OF THE ARMY NATIONAL GUARD BUREAU
Office
JFHQ USPFO OH

Point of Contact

John A. Smith
Contracting Officer
(202) 555-0100

Key Dates

Published3mo ago
Mar 3, 2026
Last Updated3mo ago
Mar 3, 2026
Became Solicitation3mo ago
Mar 3, 2026
Tracked
Response Due3mo ago
Mar 16, 2026

Description

: Bldg 1 HVAC Repair PROJECT LOCATION: Blue Ash ANGB NAICS CODE: 238220 SIZE STANDARD: $19,000,000.00 FULL AND OPEN COMPETITION DISCLOSURE OF MAGNITUDE: IAW FAR 36.204(c) Is Between $100,00 and $250,000. EMAIL ALL PROPOSALS TO: [email protected] & [email protected] DAVIS BACON WAGE RATES ARE APPLICABLE TO THIS PROJECT. PREVAILING WAGE DERTERMINATION WILL BE INCUDED AT TIME OF AWARD. BID BOND REQUIRED. SEE SITE VISIT INFORMATION UNDER FAR 52.236-27 The intent of this project is to repair the HVAC at BLDG 1 Blue Ash Air National Guard Base. The following actions must be taken to meet this intent: remove and dispose of the existing 30-ton RTU. Provide and install a new RTU; install new curbing only if required to fit the new unit. Remove the existing DDC controller and install new. Install new controls onto all HVAC components that are currently on the DDC. Provide and configure a new computer and workstation for the DDC. Remove the existing roof access ladder and hatch handrail and install new. Kurt J. Becka Alternative

Point of Contact Seth Taylor to this opportunity. Solicitation Amendment - W50S8Q26QA0010002 Professional Appearance.pdf Solicitation Amendment W50S8Q26QA0010002 SF 30.pdf Final-Solicitation Amendment-W50S8Q26QA0010001-Professional Appearance.pdf Final-Solicitation Amendment-W50S8Q26QA0010001-SF 30.pdf SOW BVGM252001-FY26.pdf (deleted) SOW BVGM252001-FY26-Revised1.pdf Binder_BLDG 1 HVAC Drawings.pdf Springfield Base Facility Standards - FINAL - March 2025 Signed.pdf Material Submittals BVGM252001.xlsx RFI Template.docx W50S8Q26QA001_Solicitation RFIs_B1 HVAC.pdf B1 Roof Plans.pdf Thermostat Photo.jpeg VAV Photo.JPG VAV Controller Photo.JPG