Quick Brief

The Department of Energy is seeking sources for the SLAC LCLS-II-HE PCW Skid Upgrade Project, which involves structural and architectural modifications, as well as mechanical, plumbing, and electrical work. Key requirements include prior experience with DOE or DOD facilities and compliance with specific qualifications related to contractor licensing and project history.

Generated 30d ago

Scope & Requirements

The project includes the installation of mechanical piping and electrical infrastructure, as well as the demolition and relocation of existing systems to support the new CO₂ chiller infrastructure.

Contract Details

Contract Type
TBD
Estimated Value
est. $12K – $123K
Similar contracts award $13K$126K (median $35K, 14,862 awards)Within typical range
NAICS Codes

Qualifications & Eligibility

Past Performance
Previous experience working at Department of Energy (DOE) and/or Department of Defense (DOD) Facilities.
Required Registrations
  • SAM.gov

Agency & Contact

Contracting Organization

Agency
ENERGY, DEPARTMENT OF

Point of Contact

John A. Smith
Contracting Officer
(202) 555-0100

Key Dates

Published3mo ago
Mar 20, 2026
Last Updated3mo ago
Mar 20, 2026
Response Due2mo ago
Mar 31, 2026
Response Date2mo ago
Apr 2, 202617:00

Description

"SOURCES SOUGHT ONLY." PLEASE DO NOT SUMBIT BIDS. While the DRAFT RFP package has been included with this post, the RFP has NOT yet been released. Interested Vendors should express their interest on the Interested Vendors List through this SAM.GOV posting or by emailing the procurement specialist. DISCLAIMER: Please note that any responses to this sources sought posting is purely on a voluntary basis. SLAC is not requesting a proposal, any

pricing, or any other information that could be considered confidential or proprietary to be submitted in response to this posting or any part of this posting. Any submissions that contain

pricing, proprietary information, or confidential information will be discarded by SLAC. MINIMUM QUALIFICATIONS: The Offeror’s General Contractor’s license has not been revoked within the past five (5) years. The Offeror’s company has not been debarred within the past five (5) years from working on any U.S. government contracts/subcontracts. Neither the Offeror’s firm, nor any of its owners or officers have been convicted of a crime involving the awarding of the contract of a government (U.S. Federal, State, and City) construction project, or the bidding or performance of a government contract. Offeror must have an established local . The San Francisco Bay Area is defined as the following 10 counties: Santa Clara, San Mateo, San Francisco, Alameda, Contra Costa, Marin, Napa, Sonoma, Solano, and Santa Cruz Counties The Offeror must list any U.S. projects within the past five (5) years that have been terminated for default. The Offeror’s company cannot have any U.S. projects within the past five (5) years that have been terminated for default. The Offeror must have previous experience working at Department of Energy (DOE) and/or Department of Defense (DOD) Facilities. PLANNED SCOPE AND DESCRIPTION OF SERVICES: 1. Room 310 CO2 Chiller Infrastructure Subcontractor shall provide labor, shop drawings, materials, and resources required to complete structural and architectural modifications, mechanical, plumbing, and electrical systems, and necessary demolitions according to the construction authorization and inspection record

requirements, construction drawings, and specifications reference #1, #2 and #3. This includes: Installation of mechanical piping, valves, and associated utilities necessary to support the chiller operation. Installation of electrical distribution infrastructure, conduit, and wiring to provide power and controls for future SLAC provided CO₂ skids. Architectural and facility modifications within Room 310 to support equipment access, installation clearances, and safety

requirements. Transportation and relocation of the 4ATS1A-950 transfer switch to the designated new location as identified in the construction drawings supporting the CO₂ Chiller Infrastructure Project. Coordination with SLAC technical teams and other contractors to ensure seamless interface with the separately managed future SLAC CO₂ skid installation and system commissioning. 2. B950A PCW Skid Demo and Relocation Subcontractor shall provide labor, shop drawings, materials, and resources required to complete structural and architectural modifications, mechanical, plumbing, and electrical systems, and necessary demolitions according to the construction authorization and inspection record

requirements, construction drawings, and specifications reference #4, #6, and #7. This includes: Disconnect and safely remove the existing B950A PCW skid located in the NEH, including associated mechanical, electrical, and control connections. Perform necessary demolition of piping, supports, and ancillary equipment for relocation, including flushing. Relocate reusable components and equipment to the designated staging or storage area identified by SLAC. Cap and label all disconnected utilities per SLAC standards. Coordinate with SLAC’s Technical Systems and Facilities Engineering to ensure that no disruption occurs to other critical cooling loops. Manage and dispose of all demolition debris and fluids per SLAC ESH and waste management procedures. 3. B950 PCW System Upgrade Subcontractor shall provide labor, shop drawings, materials, and resources required to complete structural and architectural modifications, mechanical, plumbing, and electrical systems, and necessary demolitions according to the construction authorization and inspection record