Amendment 0001 to Request for Quotation for Generator Descriptions at VAMC

Veterans Affairs (VA) > 245-NETWORK CONTRACT OFFICE 5 (36C245)Sol: 36C24526Q0401
SDVOSB

This opportunity is closed

The response deadline has passed. Review the details for future reference or to track similar opportunities.

Quick Brief

The Department of Veterans Affairs is procuring maintenance and repair services for generators at the Louis A Johnson VA Medical Center. The work includes monthly, quarterly, semi-annual, annual, and triennial maintenance, as well as load bank testing. The contract is set aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB).

Generated 56d ago

Scope & Requirements

The contractor will perform maintenance and repair on various generators located at the Louis A Johnson VA Medical Center, ensuring compliance with maintenance schedules and conducting load bank testing.

Contract Details

Estimated Value
Not specified
Similar contracts award $9K$60K (median $22K, 17,163 awards)
Incumbent Contractor
Mountaineer Generator
NAICS Codes
Set-Asides
SDVOSB

Qualifications & Eligibility

Set-Aside Category
SDVOSB

Agency & Contact

Contracting Organization

Agency
VETERANS AFFAIRS, DEPARTMENT OF
Sub-Agency
VETERANS AFFAIRS, DEPARTMENT OF
Office
245-NETWORK CONTRACT OFFICE 5 (36C245)

Point of Contact

John A. Smith
Contracting Officer
(202) 555-0100

Key Dates

Last Annual Maintenance Completed2mo ago
Mar 28, 2026
Published2mo ago
Apr 8, 2026
Last Updated2mo ago
Apr 8, 2026
Became Solicitation2mo ago
Apr 8, 2026
Tracked
Response Due1mo ago
May 1, 2026

Description

A JOHNSON VAMC VETERANS AFFAIRS, DEPARTMENT OF VETERANS AFFAIRS, DEPARTMENT OF -NETWORK CONTRACT (36C245) Service-Disabled Veteran-Owned Small Business (SDVOSB) NT/REPAIR/REBUILD OF EQUIPMENT- MAINTENANCE AND REPAIR SHOP EQUIPMENT pment (except Automotive and Electronic) Repair and Maintenance

Place of Performance Department of Veterans Affairs Louis A Johnson VA Medical Center GENSET #1 GENSET #2 GENSET #3 Manufacturer/Make/Year: Caterpillar Caterpillar Kato Model No: SR-4 C32 500SS9D Serial/Order No: 6NA01031 G1G00044 7319 Load Rating: (Emergency/Standby/Prime) 1000 kva 1250 kva 625KVA Power Factor: .8 .8 .8 Frequency: 60 Hertz 60 Hertz 60 hertz Load in Amperage: 1000 amps 1000 amps 87 Output Voltage: 480 480 volts 4160 volts Phase: 3-phase 3-phase 3-phase Building: Bld 17 Bld 17 Bld 17 Location (Area/Room): Generator room Generator Rm Generator Rm GENSET #4 GENSET #5 (portable) Manufacturer/Make/Year: Kohler Baldor Model No: 100RE0ZJF TS225-3J Serial/Order No: 3346GMJL0001 P1205240012 Load Rating: (Emergency/Standby/Prime) 128 kva 225 kva Power Factor: .8 .8 Frequency: 60 Hertz 60 Hertz Load in Amperage: 153 amps 625 amps Output Voltage: 480 480 volts Phase: 3-phase 3-phase Building: Parking Garage Grounds Location (Area/Room): Parking Garage Grounds (portable) Who will be responsible for the generator maintenance (monthly, quarterly, semi, annual, & triennial) an when was the last time the annual maintenance was completed? Mountaineer Generator. When was the last annual load bank testing conducted? Â Â Â Â Â Â Â Â Â Â Â Â Â 3/28/26. Does the KATO 500kW (625KVA) 4160v generator have an integrated load bank? NO Bill Pratt

Get matched to contracts like this daily

Free AI-powered contract matching for your business.