ActiveSources Sought
Save

Aberration-Free Imaging Spectrograph

Dept. of Commerce > National Institute of Standards & TechnologySol: NIST-SS26-157
TBD
est. $150K – $450K

This is a Sources Sought notice

The agency is researching potential vendors before issuing a formal solicitation. Responding shows your capabilities and can influence the final RFP.

Quick Brief

The Department of Commerce, specifically the National Institute of Standards and Technology (NIST), is seeking an aberration-free imaging spectrograph for the development of a new measurement and calibration capability. The spectrograph must meet specific technical requirements, including compatibility with Hamamatsu’s single-photon digital camera and advanced optical specifications to ensure high imaging quality.

Generated 7d ago

Can you respond to this?

Get your fit score, win probability, and required capabilities.

Fit Score7/10Consider

Attachments

No files on SAM.gov

This listing does not include downloadable attachments. The solicitation details may be in the description below.

Verify on SAM.gov

Contract Details

Contract Type
TBD
Estimated Value
est. $150K – $450K
Similar contracts award $14K to $90K (median $33K, 26,980 awards)Above typical range
Incumbent Contractor
Teledyne Princeton Instruments
NAICS Codes

Agency & Contact

Contracting Organization

Agency
COMMERCE, DEPARTMENT OF
Sub-Agency
National Institute of Standards and Technology

Point of Contact

John A. Smith
Contracting Officer
(202) 555-0100

Key Dates

Published9d ago
Jul 16, 2026
Became Solicitation8d ago
Jul 16, 2026
Tracked
Became Special Notice8d ago
Jul 17, 2026
Tracked
Last Updated7d ago
Jul 17, 2026
Response Date2d ago
Jul 23, 202612:00 PM EDT
Response Dueyesterday
Jul 23, 2026

Description

Combined Sources Sought Notice and Notice of Intent to Award a Sole Source Contract for Aberration-free imaging spectrograph Notice ID: NIST-SS26-157 Contract Opportunity Type: Sources Sought Response Date: 7/23/26 (PSC): 6640 NAICS Code: 334516

BACKGROUND The National Institute of Standards and Technology (NIST) is conducting market research to identify alternative sources that (a) are capable of meeting NIST’s minimum

requirements for the following commercial products and commercial services and (b) would be interested in competing for that requirement: The National Institute for Standards and Technology’s (NIST) Sensor Science Division (SSD) is involved in the development of a new measurement and calibration capability using a single photon spectroradiometer for calibration of extremely dim light sources such as nano-LEDs, LEDs used for calibration of photon-multiplier tubes, and sphere sources used for calibration of night vision goggles. The single photon spectroradiometer is composed of an aberration-free imaging spectrograph to achieve the highest imaging quality and a single photon digital camera to measure single photon sources. This acquisition is for the aberration-free imaging spectrograph. NIST requires one aberration-free imaging spectrograph that is compatible with Hamamatsu’s single-photon digital camera Model Orca-Quest 2 NIST requires an aberration-free imaging spectrograph that meets the following minimum specifications: 1. 100 % compatible with Hamamatsu’s Orca-Quest 2 digital cameras for system integration. 2. LabVIEW software for control and data acquisition. 3 .Aberration-free 320 mm focal length Schmidt-Czerny-Turner imaging spectrograph with advanced optics and superior MTF and spectral resolution. 4. Interchangeable motorized triple grating turret with torque-limiting kinematic mount. 5. f/4.6 aperture ratio. 6 .Linewidth (FWHM) of 1.5 pixels or better with a 20 micron pixel pitch. 7. Spectral resolution of 0.065 nm or better at 546 nm with a 1200 groove/mm grating. 8. Spatial resolution ≥25 line pairs/mm @ 50% modulation, measured at focal plane center 9. Spatial resolution ≥10 line pairs/mm @ 50% modulation, measured over 27 x 8 mm focal plane 10. Zero astigmatism at any wavelength with any grating at all points in the focal plane. 11. Zero coma at 500 nm with 1200 gr/mm grating. 12. Wavelength accuracy of 0.2nm. 13. Wavelength Repeatability of +/- 0.015 nm. 14. Internal angle of 17.7°. 15. Mirror focusing with internal micrometer adjustment. 16. On-axis grating rotation design. 17. Planar 68 x 68 mm gratings are on extra-thick substrates for improved flatness. 18. Motorized or kinematic slit(s) with optional slit shutter. 19. Shutter control port from camera at rear of instrument. 20. Can resolve >200 distinct spectral channels on 2D arrays on CCD and CMOS cameras up to a height of 22 mm. NIST has not yet determined its acquisition strategy for this requirement and encourages interested sources to respond to this Notice. If NIST’s market research indicates there are alternative sources that are capable and interested in competing to fill this requirement, separate and apart from [Teledyne Princeton Instruments SRAYE6X6EAL8] then NIST will consider conducting a competitive acquisition in accordance with law and regulation. To be clear, NIST’s identification of [SmarAct Inc] in this Notice does not constitute a binding commitment or obligation for it to conduct a sole source procurement with [Teledyne Princeton Instruments] for this requirement. Instructions for Responding to Respond to This Notice Parties that respond to this Notice are requested to voluntarily submit the requested information via email in Microsoft Word, Adobe PDF, and/or Microsoft Excel format to the designated point(s) of contact whose name and email address appears at the bottom of this notice. Please provide only the information requested by this Notice, and do not include proprietary, classified, confidential, or sensitive information in a response to this Notice. Information Requested in Response to This Notice: To help NIST with its market research, NIST is requesting that industry sources carefully review this notice and any

attachments to it and voluntarily provide the following information: Company Summary Notice Identification: Title of this posting. Corporate Details: Company name, physical address, website address, and Unique Entity Identifier (UEI).

Point of Contact (POC): Name, phone number, and email address. Company Size Standard: Your company’s size status relative to the NAICS code provided in this Notice. (Refer to the SBA Table of Small Business Size Standards). System for Award Management (SAM) Registration: Indicate whether your company has an active registration for procurement purposes in SAM.gov. Feedback for Draft

Requirements Review the potential

Get matched to contracts like this daily

Free AI-powered contract matching for your business.