ActiveSources Sought
Save

Determine Availability of Building HVAC System Direct Digital Controllers

Department of Defense (DoD) > Navfac Midlant
TBD
est. $50K – $250K

This is a Sources Sought notice

The agency is researching potential vendors before issuing a formal solicitation. Responding shows your capabilities and can influence the final RFP.

Quick Brief

The Department of Defense is seeking information on the availability of Facility Related Control Systems (FRCS) building heating, ventilating, and air conditioning (HVAC) system Direct Digital Controllers with specific capabilities for Naval Weapons Station Earle. Key requirements include compatibility with Honeywell WEBs software, connection to the Building Automation Network, and the ability to obtain Authority to Operate certification as per Department of Defense standards.

Generated 2h ago

Can you respond to this?

Get your fit score, win probability, and required capabilities.

Fit Score7/10Consider

Attachments

No files on SAM.gov

This listing does not include downloadable attachments. The solicitation details may be in the description below.

Verify on SAM.gov

Contract Details

Contract Type
TBD
Estimated Value
est. $50K – $250K
Similar contracts award $2K to $22K (median $7K, 4,025 awards)Above typical range
Period of Performance
2026-2031
NAICS Codes
Place of Performance
Colts Neck, NJ, USA

Agency & Contact

Contracting Organization

Agency
DEPT OF DEFENSE
Sub-Agency
NAVFAC MIDLANT

Point of Contact

John A. Smith
Contracting Officer
(202) 555-0100

Key Dates

Publishedyesterday
Jul 23, 2026
Last Updatedyesterday
Jul 23, 2026
Became Solicitationtoday
Jul 23, 2026
Tracked
Sought Response Datein 13d
Aug 6, 202614:00
Response Duein 14d
Aug 7, 2026

Description

Naval Facilities Engineering Systems Command, Mid-Atlantic (NAVFAC MIDLANT), is issuing this Sources Sought Notice for market research purposes only. This notice does NOT constitute a request for proposal, quote, and/or invitation for bid. The purpose of this notice is to determine the availability of Facility Related Control Systems (FRCS) building heating, ventilating, and air conditioning (HVAC) system Direct Digital Controllers with the following salient characteristics from responsible sources: 1. Capability of controlling Heating, Ventilating, and Air-Conditioning (HVAC) systems. 2. Capability of being operated using Honeywell WEBs licensed software for their configuration and programming to create, modify, and download control programming, database, graphics, and controller configuration files and shall be installed by manufacturer authorized/trained/certified companies and individuals. 3. Capability to connect to the Building Automation Network (BAN) at Naval Weapons Station Earle, Colts Neck, New Jersey. 4. Capability to obtain and maintain Authority to Operate (ATO) certification in accordance with Department of Defense Instruction (DODI) 8500.01 and DODI 8510.01.

BACKGROUND: NAVFAC MIDLANT is working on a Class Justification and Approval (J&A) for various projects at Naval Weapons Station Earle, Colts Neck, New Jersey. This Class J&A would authorize the inclusion of brand-name specifications, under the authority of 10, U.S.C. 3204(a)(1) for Direct Digital Controllers utilizing Honeywell software for Configuration/Programming and for Connection to the BAN located at Weapons Station Earle, Colts Neck, New Jersey. It is anticipated that the proposed Class J&A will cover various construction projects from Fiscal Year (FY) 2026 to 2031. •The Honeywell (Niagara-based) Building Management System (BMS) is a type of Direct Digital Controller (DDC) System that monitors and controls the HVAC system for a building. •The Honeywell BMS consists of several hardware components including but not limited to; WEB-8000 controllers, WEBS N4-JACE, Optimizer Unitary branded controllers, general purpose controllers, unitary controllers, BACnet controllers, VAV controllers and zone controllers. •The Honeywell BMS also consists of the software necessary to operate the system in addition to allowing the integration of multiple Honeywell Building Management Systems. •Further technical specifications pertaining to the Honeywell BAS can be found on Honeywell’s website at: https://buildings.honeywell.com/us/en/brands/our-brands/bms/ Based on internal Government research, the following was found to be sufficient preliminary rationale to permit other than full and open competition under the authority of 10, U.S.C. 3204(a)(1), Only One Responsible Source/Limited Number of Sources and No Other Type of Property or Services Will Satisfy the Needs of the Agency. 1. Establish and maintain a defensible cybersecurity posture. 2. Maximize utilization of existing government-licensed software to configure and program the controllers. 3. Maintain installation networked facilities control and monitoring system so that all controllers can be programmed from a central station versus a hybrid system composed of many different controllers and associated configuration/programming software 4. Avoid the significant operational burden and cost of having maintenance and engineering staff become proficient with the configuration, programming, commissioning, operation, and maintenance of controllers from multiple manufacturers. INSTRUCTIONS TO INTERESTED PARTIES: Please note that this is not a Request for Proposal (RFP), a promise to contract, or a commitment of any kind on the part of the Government. There will be no debrief, evaluation letters, and/or results to be issued to interested parties that choose to respond. Information obtained from this Sources Sought Notice is for market research purposes to determine whether another companies’ similar products can meet, or be modified to meet, the Governments needs which will facilitate the decision making process. All information received in response to this Sources Sought Notice marked or designated as proprietary information will not be released outside the Government. The Government shall not reimburse or assume any cost incurred by interested parties that respond to this notice. Interested parties shall provide the following: 1. Company Information – Attachment 1 2. Direct Digital Controllers Technical Information: Provide a list of commercially available direct digital controllers, manufactured by your organization, for which Honeywell software (WEBs) have been utilized to create, modify, and download control programing, database, graphics, and controller configuration files. Include the following information for each controller: a. Model Number, Catalog Number, Code Number, or equivalent model designation b. Product Description c. Controller Application (please specify): ‘Building Level Controller’ or ‘Zone Controller’ or ‘Equipment Controller’ or ‘Other' d. Communications Protocol: ‘BACnet’ e. Manufacturer's technical data sheets. 3. Experience (3 pages maximum): Identify one (1) to three (3) installed systems Honeywell software (WEBs) has been used to successfully program and configure non-Honeywell direct digital controllers presented under item 1 above, which serve Heating, Ventilating, and Air Conditioning (HVAC) systems. For each project, provide: a. Customer

Point of Contact including name, phone number, and email b. Narrative Description of the product/services provided by your organization c. If available, Project information including title, project location (city/state), procurement contract number, and contract value. Responses to this notice shall be sent electronically to Holly Manning, Contract Specialist, at [email protected] no later than 2:00pm EST on 8/6/26. Hardcopy or facsimile submissions shall not be accepted or considered by the Government. Responses received after the deadline or without the required information shall not be considered by the Government. Holly N. Manning Contracting (No Street Address

2) NORFOLK, VA 23511-0395 USA to this opportunity.

Get matched to contracts like this daily