Repair and Replace Hangar Roof Building 11525

Department of Defense (DoD) > U.S. Air ForceSol: FA500026Q0025
SBFFP
est. $1.1M – $2.2M

This opportunity is closed

The response deadline has passed. Review the details for future reference or to track similar opportunities.

Quick Brief

The Department of the Air Force is procuring the repair and replacement of the roof for Hangar B11525 at Joint Base Elmendorf-Richardson, Alaska. The project requires the removal of existing built-up roofing and the installation of a 3-ply SBS-Modified BUR roof assembly and a 90-mil EPDM roof assembly. Key requirements include replacing roof drains, flashings, vapor barriers, and metal copings on a historic steel and concrete structure.

Generated 22d ago

Scope & Requirements

Remove existing built-up roof from a historic hangar and replace it with a 3-ply SBS-Modified BUR roof assembly and a 90-mil EPDM roof assembly, including all associated flashings and drains.

Deliverables

  • 3-ply SBS-Modified BUR roof assembly with granular cap sheet
  • 90-mil Ethylene Propylene Diene Monomer (EPDM) roof assembly
  • New roof drains
  • New flashings and vent pipe flashing
  • New cover board, vapor barrier, and cant strips
  • New metal copings and trim

Contract Details

Contract Typei
FFP
Estimated Value
est. $1.1M – $2.2M
Similar contracts award $26K to $369K (median $93K, 3,051 awards)Above typical range
NAICS Codes
Place of Performance
JBER, Alaska, USA
Set-Asides
SB

Agency & Contact

Contracting Organization

Agency
DEPT OF DEFENSE
Sub-Agency
PACIFIC AIR FORCES

Point of Contact

John A. Smith
Contracting Officer
(202) 555-0100

Key Dates

Site visit2mo ago
Jun 8, 202612:00PM
Published23d ago
Jul 2, 2026
Became Solicitation23d ago
Jul 2, 2026
Tracked
Last Updated23d ago
Jul 2, 2026
Response Due17d ago
Jul 7, 2026

Description

for 8 June, 2026, at 12:00PM. Building 11525 is a one-story, 113,000 square feet (SF) building framed from steel and cast concrete (beams and columns with CMU infill). The building was originally constructed in the early 1940s and is a historic property. The high barrel roof section that?s approximately 200-ft (curved) by 280-ft, two low roof low sections that are approximately 35-ft by 280-ft each, and one low roof section that approximately 62 ft by 242 ft. This project will remove the existing built-up roof (BUR) from both barrel center section and the east side roof low section identified in Sheets AD-101 and A-101, down to the existing decking and replaced with new 3-ply SBS-Modified BUR roof assembly with granular cap sheet on the barrel roof section and the south lower roof low section shall be replaced with a new 90-mil Ethylene Propylene Diene Monomer (EPDM) roof assembly. All roofing assemblies shall be fully adhered. Replace existing roof drains, flashings, vent pipe flashing, cover board (as required), vapor barrier, cant strips, metal copings and trim with new. Christopher Nelson Alternative

Point of Contact Robin Cole-Barden

Get matched to contracts like this daily