Install Boiler Fuel Reserve Tank at Loch Raven VA Medical Center

Veterans Affairs (VA)
est. $30K – $100K

This opportunity is closed

The response deadline has passed. Review the details for future reference or to track similar opportunities.

Quick Brief

The Department of Veterans Affairs is procuring a Boiler Fuel Reserve Tank for the Loch Raven VA Medical Center. Key requirements include measuring instruments for gas flow, liquid level, and mechanical motion, as well as ensuring compatibility with the existing Veeder Root monitoring system.

Generated 61d ago

Scope & Requirements

The work involves the installation of a Boiler Fuel Reserve Tank at the Loch Raven VA Medical Center, including necessary measuring instruments and ensuring compatibility with existing systems.

Contract Details

Estimated Value
est. $30K – $100K
Similar contracts award $3K$37K (median $10K, 6,655 awards)Above typical range
NAICS Codes
Place of Performance
Loch Raven, MD, USA

Qualifications & Eligibility

Set-Aside Category
Total Small Business

Agency & Contact

Contracting Organization

Agency
VETERANS AFFAIRS, DEPARTMENT OF

Point of Contact

John A. Smith
Contracting Officer
(202) 555-0100

Key Dates

Published2mo ago
Mar 31, 2026
Last Updated2mo ago
Mar 31, 2026
Became Solicitation2mo ago
Mar 31, 2026
Tracked
Response Due2mo ago
Apr 2, 2026
Solicitation Close Date2mo ago
Apr 6, 202612:00 PM

Description

This amendment is to answer the following

questions: What is the distance from the new tank location to the Boiler Room? This distance is approximately 40 feet. Picture attached. Is there an existing electrical source near the proposed tank location suitable for powering pumps, leak detection, or monitoring equipment? Yes, the shop recommends G-17 and running a cord to an outlet or tying into one of the panels inside. This will be determined in the field. Does the facility currently hold an oil storage or oil burning operating permit? Yes, the facility does hold an oil storage permit. Please confirm the model number of the existing Veeder Root monitoring system so we can verify compatibility with the new tank installation. Model: TLS-450 Plus The solicitation will be closed on Monday, 4/6/2026 at 12PM EST. Theresa Thomas to this opportunity. image.png 36C24526Q0377_4.docx 36C24526Q0377_3.docx Loch Raven Diagram for Boiler Fuel Reserve_3.24.26.pdf 36C24526Q0377_2.docx 36C24526Q0377 Reserve Fuel Tank.pdf