Water Valve Leak Mitigation

Dept. of EnergySol: FMP-NNL-0047
TBD
est. $50K – $5.5M
Quick Brief

The Department of Energy is seeking information on methods to mitigate water leakage from valves during maintenance on pure water fluid systems. The desired solutions should not affect water chemistry or introduce materials that need removal post-repair, and must be non-intrusive. This request is for market research purposes and does not constitute a solicitation.

Generated 14d ago

Can you win this contract?

Get your fit score, win probability, and required capabilities.

Fit Score7/10Consider

Scope & Requirements

The work involves identifying methods to prevent water leakage from valves during maintenance on pure water systems.

Attachments

No files on SAM.gov

This listing does not include downloadable attachments. The solicitation details may be in the description below.

Verify on SAM.gov

Contract Details

Contract Type
TBD
Estimated Value
est. $50K – $5.5M
Place of Performance
Schenectady, NY, USA

Agency & Contact

Contracting Organization

Agency
ENERGY, DEPARTMENT OF

Point of Contact

John A. Smith
Contracting Officer
(202) 555-0100

Key Dates

Published15d ago
Jul 9, 2026
Became Solicitation14d ago
Jul 9, 2026
Tracked
Last Updated14d ago
Jul 10, 2026
Response Datein 1mo
Sep 3, 202617:00
Response Duein 1mo
Sep 3, 2026

Description

A REQUEST FOR INFORMATION ONLY.

THIS IS NOT A SOLICITATION. This notice is issued solely for informational and planning purposes. This notice does not constitute a solicitation. The Naval Nuclear Laboratory (NNL), operated by Fluor Marine Propulsion (FMP), is utilizing this request for information for market research to determine what organizations have the capability to fulfill this requirement. NNL will not be responsible for any costs incurred by interested parties in responding to this request for information. Responses shall not exceed five (5) pages in length. Scope: When performing maintenance on a pure water fluid system, valves are commonly used for work area isolation. Valves that have been in-service can leak past their seats. In this case, the worker may still be protected from hazardous energy on the other side of the valve but work such as welding might not be possible if water is being continually introduced to the work area. In this case, more valves can be used if available in the system design, but if not, freeze seals are commonly used to eliminate leakage. Freeze seals can consume significant work and resources to set, so alternate means to mitigate water leakage past valves is desired. A method to mitigate valve leak-by for the hours or days a system is open for maintenance or the time to perform a weld is desired which will not affect pure water chemistry or stainless-steel corrosion or cracking performance. The method must not introduce devices or materials that require removal from the system after repair is completed. Solutions must either be external to the system, completely dissolve into known and consistent constituents at room temperature, or otherwise non-intrusive. ATIP Contracting , c/o Fluor Marine Propulsion, LLC P.O. Box 1072 Schenectady, NY 12301 USA to this opportunity.