Safety Shower and Eyewash Corrections Phase One

Dept. of Commerce > National Institute of Standards & Technology > DEPT OF COMMERCE NIST
est. $13K – $33K

This opportunity is closed

The response deadline has passed. Review the details for future reference or to track similar opportunities.

Quick Brief

The Department of Commerce is procuring contracted construction services to correct deficiencies in safety showers and eyewashes at the NIST Boulder Campus. The project aims to ensure compliance with ANSI Z358.1-2014 standards across multiple buildings, including design and construction work.

Generated 32d ago

Scope & Requirements

The contractor will evaluate and confirm the viability of recommendations for safety shower and eyewash corrections, provide engineered designs, and execute construction to ensure compliance with safety standards.

Contract Details

Estimated Value
est. $13K – $33K
Similar contracts award $13K$126K (median $35K, 14,862 awards)Within typical range
NAICS Codes
Place of Performance
Boulder, CO, USA

Qualifications & Eligibility

Set-Aside Category
FAR 19.5

Agency & Contact

Contracting Organization

Agency
COMMERCE, DEPARTMENT OF
Sub-Agency
NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY
Office
DEPT OF COMMERCE NIST

Point of Contact

John A. Smith
Contracting Officer
(202) 555-0100

Key Dates

Published1mo ago
May 1, 2026
Last Updated1mo ago
May 1, 2026
Project Completion Date1mo ago
May 1, 2026
Became Sources Sought1mo ago
May 1, 2026
Tracked
Response Due23d ago
May 12, 2026

Description

: 1. 1333ND26RNB190015 Eyewash Phase 1 NIST Boulder CO.pdf, and 2. OFPM Site Standards.zip

Background Information The Department of Commerce (DOC) campus is a research and development complex located at 325 Broadway in Boulder, Colorado. The National Institute of Standards and Technology (NIST) is the primary occupant, National Oceanic Atmospheric Administration (NOAA) and National Telecommunications and Information Administration (NTIA) also have a presence on campus. NIST’s (OFPM) is responsible for maintaining and renovation of spaces which consist of laboratories, . Annual testing of safety showers and eyewashes across campus have shown a significant number of fixtures failing to meet the ANSI Z358.1-2014 (Emergency Eyewash & Shower Standard), mostly shower/eyewash combination fixtures that fail during simultaneous operation. OFPM conducted a study which identified deficient fixtures, determined the cause of failure, and recommended necessary actions to bring the fixtures into compliance. Purpose Many of the deficiencies identified have been remedied by NIST OFPM employees completing the recommended corrective actions. However, the scope in some buildings/areas is large enough to warrant contracted construction: Building 22 (B22), Building 25 (B25), Building 42 (B42/Central Utility Plant – CUP), Building 1 (B1), and Building 2 (B2) all have emergency fixtures needing attention. The intent of this project is to remedy the remaining deficiencies such that all emergency fixtures are compliant with ANSI Z358.1-2014. This Design-Build project is structured with B22 as the base scope and four option CLINs for the other abovementioned areas. Recommendations presented in this SOW and supporting documents are intended to be an optional starting point. Additional design and coordination will be necessary to proceed with any of the recommendations. It is the responsibility of the contractor to evaluate and confirm the viability of the recommendations, provide an engineered design, and execute the construction to successfully bring all fixtures within project scope into compliance.

PLACE OF PERFORMANCE: NIST Boulder Campus, Boulder, CO Shawn Borisow Contracting . GAITHERSBURG, MD 20899 USA to this opportunity.

Get matched to contracts like this daily

Free AI-powered contract matching for your business.