Closed
Save

Enhanced Vyleater Vial Disposal System Model II-Xe

Department of Defense (DoD) > U.S. ArmySol: PANHCA-26-029301
FFP

This opportunity is closed

The response deadline has passed. Review the details for future reference or to track similar opportunities.

Quick Brief

The Department of Defense is procuring the Enhanced Vyleater Vial Disposal System Model II-Xe for the Department of Pathology and Area Laboratory Services at the San Antonio Military Medical Center. Key requirements include the device's ability to accommodate whole vials, explosion resistance, compliance with hazardous waste guidelines, and the provision of training for technicians. The anticipated award will be a Firm Fixed-Price purchase order.

Generated 19d ago

Scope & Requirements

The work involves providing the Enhanced Vyleater Vial Disposal System Model II-Xe, which includes delivery, installation, and training for technicians at the San Antonio Military Medical Center.

Contract Details

Contract Typei
FFP
Estimated Value
Not specified
Similar contracts award $259$25K (median $5K, 45,761 awards)
NAICS Codes
Place of Performance
Fort Sam Houston, TX, USA

Qualifications & Eligibility

NAICS Size Standard
1000 employees

Agency & Contact

Contracting Organization

Agency
DEPT OF DEFENSE
Sub-Agency
US Army Medical Command
Office
Medical Readiness Contracting Office - West

Point of Contact

John A. Smith
Contracting Officer
(202) 555-0100

Key Dates

Published20d ago
May 15, 2026
Became Solicitation19d ago
May 15, 2026
Tracked
Last Updated18d ago
May 17, 2026
Response Date6d ago
May 29, 202612:00 PM
CDT
Response Due5d ago
May 29, 2026

Description

The Medical Readiness

Contracting Office - West (MRCO-W) has an upcoming requirement for Enhanced Vyleater Vial Disposal System Model II-Xe., for the Department of Pathology and Area Laboratory Services (DPALS), San Antonio Military Medical Center (SAMMC), Fort Sam Houston, TX. The Government anticipates awarding a Firm Fixed-Price purchase order for this requirement. The proposed North American Industry System (NAICS) Code is – 339112, Surgical and Medical Instrument Manufacturing, business size standard of 1000 employees. Responses to the Sources Sought Notice should demonstrate the firm's ability, capability, and responsibility in providing the items listed above. Do not submit

pricing information in response to this Sources Sought. Interested sources should submit a Statement of Capability (3-page limit) detailing their capability to provide the surgical equipment requested to Brooke Army Medical Center (JBSA Fort Sam Houston, TX). Additionally, please provide the following information:

1) Organization's name, CAGE code, address,

point of contact, phone number, and e-mail address. Please advise if the requirement can be met through a contract vehicle the source already has (i.e. VA FSS contract number). Contractors responding to this sources sought notice are advised their response does not ensure participation in future solicitations or contract awards. The Government will not reimburse any company or individual for any expense associated with preparation or participation in this research. Interested parties should e-mail responses to [email protected] ADDITIONAL INFORMATION Item: Vyleater Manufacturer/Vendor: S&G Enterprises, Inc. Model: model II-XE Quantity: 1 EA Purchase Method: One-time buy Minimum Clinical Performance

Requirements SALIENT CHARACTERISTICS • The device must be able to accommodate vials in their whole form • The device must be explosion resistant to substances with a flash point of 27 °C / 81 °F • The devise should separate solid waste materials in a separate container from the liquid waste. • The device should be self-contained • The disposal system must comply with hazard waste guidelines • The device should not alter the waste material • The device should come with training for all technicians that will be required to utilize it • The device should be able to withstand mild exposure to environmental elements, ie sun, humidity, wind • The device needs to accommodate approximately 300 vials being disposed of per day, with each vial holding approximately 20ml of methanol-based solution • The regional technical support and service from manufacturer should be available in case that the parts need to be ordered to repair • The operators training support should be available as requested. • The device should be simple and easy to use for non-experienced operators • The device should be durable and easy to clean Source Considerations • Power source: line operation • Voltage

Get matched to contracts like this daily