Closed
Save

Single Purchase of Agilent 8890 GC System with Dual ECD Detectors

EPASol: 68HE0426Q0008
fixed price
$350K

This opportunity is closed

The response deadline has passed. Review the details for future reference or to track similar opportunities.

Quick Brief

The EPA intends to award a sole-source contract to Agilent Technologies, Inc. for the purchase, delivery, and installation of an Agilent 8890 GC System with dual ECD detectors for performing PCB and pesticide analysis on soil and water samples.

Generated 57d ago

Scope & Requirements

Purchase, delivery, and installation of an Agilent 8890 GC System with dual electron capture detectors and dual split/splitless inlets for performing PCB and pesticide analysis on soil and water samples.

Deliverables

  • Agilent 8890 GC System with dual ECD detectors
  • Dual split/splitless inlets
  • Autosampler with 150 sample positions
  • Installation and setup

Attachments

No files on SAM.gov

This listing does not include downloadable attachments. The solicitation details may be in the description below.

Verify on SAM.gov

Contract Details

Contract Type
fixed price
Contract Vehicle
Simplified Acquisition Procedures
Contract Value
$350K
Similar contracts award $11K$140K (median $35K, 5,089 awards)Above typical range
simplified acquisition threshold
Incumbent Contractor
Agilent Technologies, Inc.
Expected Awards
1
NAICS Codes
Place of Performance
Atlanta, GA, USA

Agency & Contact

Contracting Organization

Agency
ENVIRONMENTAL PROTECTION AGENCY
Sub-Agency
ENVIRONMENTAL PROTECTION AGENCY
Office
REGION 4 CONTRACTING OFFICE

Point of Contact

John A. Smith
Contracting Officer
(202) 555-0100

Key Dates

Published2mo ago
Mar 26, 2026
Last Updated2mo ago
Mar 26, 2026
Response Due2mo ago
Apr 10, 2026
Response Datein 11mo
Apr 26, 202716:30
EDT

Description

This is a notice of intent, not a request for a quotation. A solicitation document will not be issued, and quotations will not be requested.The Environmental Protection Agency (EPA) intends to award a fixed price contract on a sole source basis to Agilent Technologies, Inc. for the purchase, delivery and installation of an Agilent 8890 GC System with dual electron capture detectors and dual split/splitless inlets.The requirement is to perform PCB and pesticide analysis on soil and water samples using multiple EPA methods including 8081B and 8082A. The autosampler must contain 150 sample positions and be able to deliver samples and standards from the sample vials into the GC inlet. The GC must contain two inlets that are electronic pneumatic controlled (EPC) with standard and inert flow path with split/splitless capillary inlet (S/SL). Agilent Technologies, Inc. is the only vendor that can supply the requisite equipment supporting efficiency and transferability of use with the supporting equipment components that result in the best value to the government.The continued use of products from this manufacturer allows for ease of continued operation, as all current analysts have been thoroughly trained in the use and maintenance of Agilent GCs. Continuity of instrumentation will also allow for easier and quicker training of new employees as well as cross-training existing employees. The new GC-ECD manufactured by Agilent Technologies, Inc., are compatible with the laboratory’s current quality system, operational equipment and existing sample analysis policies and procedures. As a result, procurement from the vendor represents the best value to the government and provides the only source of supply.This purchase will be made utilizing Simplified Acquisition Procedures in accordance with Federal Regulation (FAR) Part 13.106-1(b)(1) for purchases not exceeding the simplified acquisition threshold of $350,000.00. Pursuant to the authority granted by 41 U.S.C.253(c) (1), only one responsible source and no other supplies or services will satisfy agency

requirements as implemented by FAR 6.302-1. The U.S. Environmental Protection Agency (EPA), ’s Acquisition and Grants Management’s Branch intends to issue a task order to Agilent Technologies, Inc. for the purchase, delivery and installation of an Agilent 8890 GC System.The sole source nature of this requirement is based on the determination Agilent Technologies, Inc is the only organization that can support this requirement. Market research reflects that Agilent Technologies, Inc. is the only source for the Agilent 8890 GC System. No other source meets the requirement.The determination not to compete this proposed contract action is solely within the discretion of the Government. Information received will normally be considered for the purposes of determining whether to conduct a competitive procurement. The Government will not be responsible for any costs incurred by responding to this notice.

Questions or comments to this Notice of Intent should be directed to the

Contracting Officer, Megan Wallace, [email protected] and/or the Contract Specialist, Femi Obadina, [email protected]. Please indicate in the subject of your email: Notice of Intent Submission: Requisition PR-R4-26-00172. Wallace, Megan Phone Number (513) 569-7927 Contracting , S.W. ATLANTA, GA 30303 USA

Get matched to contracts like this daily