The Department of Defense is procuring inspection, diagnosis, and repair services for three MEGA Door brand vertical lift hangar doors located at the 187th Fighter Wing in Montgomery, AL. The contractor will need to address issues related to metal shavings during door operation and provide all necessary labor, tools, and OEM parts to restore the doors to full operational status. A site visit is scheduled for May 27, 2026, and proposals are due by June 5, 2026.
Get your fit score, win probability, and required capabilities.
The contractor will perform a comprehensive inspection and diagnostics of the hangar doors, followed by necessary repairs and preventative maintenance to ensure safe operation.
for Commercial Services This is a combined for commercial services prepared in accordance with the format in Federal Acquisition Regulation (FAR) subpart 12.202, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued. Solicitation Number: W50S6N-26-Q-A020 Issued as: Request for Quote (RFQ) Description: This solicitation is for the inspection, diagnosis, and repair of three (3) MEGA Door brand vertical lift hangar doors located at the 187th FW, in accordance with the provided Statement of Work. The primary issue to be addressed is the generation of metal shavings during door operation. Set-Aside Status: This acquisition is issued on a full and open competition basis and is not set-aside for small business concerns. This solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2026-01. dated 03/13/2016. The full text of provisions and clauses may be accessed electronically at www.acquisition.gov. 1. List of Line Items CLIN 0001: Inspection, Diagnosis, and Repair of Hangar Doors Item: Furnish all necessary labor, tools, equipment, supplies, and expertise to inspect, diagnose, and repair three (3) MEGA Door brand vertical lift hangar doors (two on building 1203, one on building 1201). Quantity: 1 Unit of Issue: Job 2. Description of
Requirements The contractor shall provide all services necessary to restore the hangar doors to full, safe, and correct operational status. The
scope of work includes, but is not limited to: Comprehensive Inspection and Diagnostics: Conduct a thorough inspection of each door to identify the source of the metal shavings and provide a detailed report of findings and a recommended plan for corrective action. Corrective Maintenance and Repair: Perform all necessary repairs, which may include component replacement, realignment, and lubrication. All replacement parts shall be Original Equipment Manufacturer (OEM) parts from MEGA Door (ASSA ABLOY) or an equivalent that meets or exceeds OEM specifications. Preventative Maintenance and Servicing: Perform a full preventative maintenance service on each door as recommended by the manufacturer. A full description of
requirements is detailed in the attached Statement of Work. 3. Date(s) and Place(s) of Performance and Acceptance
Place of Performance: 187th Fighter Wing, Dannelly Field ANGB, Montgomery, AL
Period of Performance: 30 days after award. 4. Site Visit In accordance with FAR Provision 52.237-1 Site Visit a site visit will be held for all interested offerors. The date for the site visit is