Closed
Save

Boiler Salinity System Replacement for CGC Healy

Homeland Security (DHS) > Surface Forces Logistics Center (Sflc)
est. $1.9M – $3.4M

This opportunity is closed

The response deadline has passed. Review the details for future reference or to track similar opportunities.

Quick Brief

The U.S. Coast Guard is seeking information on capabilities to provide a new boiler condensate salinity monitoring system for the USCGC HEALY. The requirement includes the removal of obsolete salinity cells and installation of a specified Burkert system, involving custom fabrication, electrical work, and system integration.

Generated 61d ago

Scope & Requirements

The work involves providing a new boiler condensate salinity monitoring system, including the removal of old equipment and installation of new components, along with necessary custom fabrication and integration.

Deliverables

  • Two (2) Burkert 8619 Multicell Controllers
  • Two (2) Burkert 8220 Conductivity Sensors
  • Custom fabricated mounting hardware
  • Full system integration with the ship’s Machinery Plant Control and Monitoring System (MPCMS)

Contract Details

Estimated Value
est. $1.9M – $3.4M
Similar contracts award $11K$140K (median $35K, 5,089 awards)Above typical range
Period of Performance
To Be Determined (TBD)
NAICS Codes
Place of Performance
Seattle, WA, USA

Agency & Contact

Contracting Organization

Agency
HOMELAND SECURITY, DEPARTMENT OF
Sub-Agency
Surface Forces Logistics Center (SFLC)

Point of Contact

John A. Smith
Contracting Officer
(202) 555-0100

Key Dates

Published3mo ago
Mar 11, 2026
Last Updated3mo ago
Mar 11, 2026
Became Solicitation3mo ago
Mar 11, 2026
Tracked
Response Due3mo ago
Mar 19, 2026
Response Due Date3mo ago
Mar 20, 202616:00
Eastern Daylight Time (EDT)

Description

(RFI) – MARKET RESEARCH PURPOSES ONLY RFI Number: 70Z08526RFI031126 NAICS Code: 228210 – Electrical Contractors and Other Wiring Installation Contractors. FSC Code: 6630 – Chemical Analysis Instruments The United States Coast Guard Deputy Commandant for Systems (DCS) is issuing this Request for Information (RFI) on behalf of the Surface Forces Logistics Center (SFLC) for market research purposes only. This notice is issued solely to obtain information from industry and does not constitute a solicitation. The Government is not requesting proposals or quotations at this time and will not award a contract based on responses to this notice. DESCRIPTION OF POTENTIAL REQUIREMENT The Government is conducting market research to identify sources capable of providing all labor, supervision, materials, and equipment necessary to procure, deliver, and install a new boiler condensate salinity monitoring system on the USCGC HEALY (WAGB-20). The anticipated requirement will include the removal and disposal of the obsolete McNab MC-81 salinity cells and the installation and integration of a new, Government-specified Burkert system. The required components include, at a minimum, two (2) Burkert 8619 Multicell Controllers and two (2) Burkert 8220 Conductivity Sensors. The

scope of work involves custom fabrication and welding of mounting hardware, shipboard electrical work, and full system integration with the ship’s Machinery Plant Control and Monitoring System (MPCMS). The anticipated

place of performance is aboard the USCGC HEALY, homeported in Seattle, WA. The estimated

period of performance is To Be Determined (TBD). REQUESTED INFORMATION The Government is interested in understanding industry capability to perform this work. Interested parties are invited to submit information demonstrating their ability to provide the services described. A full description of the requirement, technical specifications, and detailed submission instructions are included in the attached RFI document, "RFI_HEALY_Salinity_System.pdf". Responses must address the specific

questions outlined in Section 3.0 of the attached RFI, including providing a capabilities statement, information on the ability to procure the specified components, and a Rough Order of Magnitude (ROM) price estimate. SUBMISSION OF RESPONSES Interested parties must respond to this RFI no later than 4:00 PM, Eastern Daylight Time (EDT), on March 20, 2026. Responses to this notice are voluntary and will be used solely for market research purposes to assist the Government in planning a potential future acquisition. All responses shall be submitted electronically via email to the points of contact identified below. Primary POC: CWO2 Corry Thomas, [email protected] Alternate POC: Stephen Krumfolz, [email protected] The subject line of the email must read: “CGC HEALY SALINTY MONITOR RFI RESPONSE - [Company Name] - RFI #70Z08526RFI031126". Corry Thomas Alternative

Point of Contact JASON GARRIS Contracting , BLDG 50-7 (No Street Address