ActiveOpen for Bids
Save

Replace Liner Inside Structural Fire Trainer

Department of Defense (DoD) > U.S. Air Force > AIR COMBAT COMMANDSol: FA480926Q0065
SB
est. $85K – $250K
Quick Brief

The Department of Defense is procuring a Fire Trainer Liner for the Air Combat Command, which requires a specialized liner designed for extreme live-fire training. Key requirements include compliance with safety and regulatory specifications, a unique installation method, and the ability to withstand high nozzle forces, along with a warranty of five to ten years.

Generated 1d ago

Can you win this contract?

Get your fit score, win probability, and required capabilities.

Fit Score7/10Consider

Scope & Requirements

The work involves replacing the liner inside the structural trainer with a material engineered for live-fire training.

Contract Details

Estimated Value
est. $85K – $250K
Similar contracts award $17K to $211K (median $60K, 5,896 awards)Within typical range
NAICS Codes
Set-Asides
SB

Qualifications & Eligibility

Set-Aside Category
ND

Agency & Contact

Contracting Organization

Agency
DEPT OF DEFENSE
Sub-Agency
DEPT OF THE AIR FORCE
Office
AIR COMBAT COMMAND

Point of Contact

John A. Smith
Contracting Officer
(202) 555-0100

Key Dates

Published3d ago
Jul 21, 2026
Became Solicitation2d ago
Jul 21, 2026
Tracked
Last Updatedtoday
Jul 23, 2026
Response Datein 6d
Jul 30, 202614:00
Response Duein 7d
Jul 30, 2026

Description

the structural trainer

REQUIREMENTS: The liner components units shall: 1. Designed to meet all referenced safety, thermal, and regulatory specifications, this specific material is engineered for extreme live-fire training evolutions. 2. Specifically formulated for Class A, B, C, D, Electrical, and F/K fires within a controlled burn cell which complies with NFPA 1402 and related standards. 3. Made of a cementitious high temp composite formula, which has a negative health impact when installed by certified installers. 4. Have Kevlar additives 5. Unique tongue and groove installation method 6. Stainless Steel mounting hardware 7. Have five (5) to ten (10) year warranty to replace 8. Able to withstand 150 psi nozzle forces 9. 1.5 inches thick requires no additional insulation behind its barrier 10. Heat transfer 10.4% (1000 degree / 140 degree in 10 minutes) 11. Complies with all NFPA suggested burn matrix formulas 12. Certified as a protective skin for flammable hazmat storage cells Michael

A. Berg Alternative

Point of Contact Ryan Rhea to this opportunity. 02 A-01 - FLOOR PLANS.pdf Fire Trainer Drawings.png

Get matched to contracts like this daily

Free AI-powered contract matching for your business.