ActiveSources Sought
Save

Air Conditioning Unit Alignment and Preventative Maintenance

Department of Defense (DoD) > U.S. Air Force > AIR FORCE MATERIEL COMMAND
TBD
$9K – $61K per task order

This is a Sources Sought notice

The agency is researching potential vendors before issuing a formal solicitation. Responding shows your capabilities and can influence the final RFP.

Quick Brief

The Department of Defense is conducting a market survey to identify potential contractors for the alignment and preventative maintenance of Air Conditioning Units 1 and 2 at Edwards Air Force Base. The required services include the installation of a permanent condition monitoring system, ongoing data-driven maintenance, and routine inspections to enhance equipment reliability and prevent downtime. The contract will consist of one base year and four option years, focusing on transitioning to a monitored maintenance program.

Generated 15d ago

Can you respond to this?

Get your fit score, win probability, and required capabilities.

Fit Score7/10Consider

Scope & Requirements

Deliverables

  • System Implementation Report
  • Continuous Data Access & Reporting

Attachments

No files on SAM.gov

This listing does not include downloadable attachments. The solicitation details may be in the description below.

Verify on SAM.gov

Contract Details

Contract Type
TBD
Contract Value
$9K – $61K per task order
IDIQ ceiling: $1.3M
Similar contracts award $9K to $61K (median $22K, 16,576 awards)
NAICS Codes
Place of Performance
Edwards AFB, USA

Agency & Contact

Contracting Organization

Agency
DEPT OF DEFENSE
Sub-Agency
DEPT OF THE AIR FORCE
Office
AIR FORCE MATERIEL COMMAND

Point of Contact

John A. Smith
Contracting Officer
(202) 555-0100

Key Dates

Published16d ago
Jul 8, 2026
Last Updated16d ago
Jul 8, 2026
Became Solicitation15d ago
Jul 8, 2026
Tracked
Response Date11d ago
Jul 13, 202609:00 AM
PDT
Response Dueyesterday
Jul 23, 2026

Description

(s): EDWARDS AFB SOURCES SOUGHT FOR ACU 1 AND 2 ALIGNMENT AND PREVENTATIVE MAINTENANCE THIS IS A MARKET SURVEY FOR INFORMATION ONLY.

THIS IS NOT A SOLICITATION FOR PROPOSALS AND NO CONTRACT WILL BE AWARDED FROM THIS SYNOPISIS. NO REIMBURSEMENT WILL BE MADE FOR ANY COSTS ASSOCIATED WITH PROVIDING INFORMATION IN RESPONSE TO THIS SYNOPSIS OR ANY FOLLOW-UP INFORMATION REQUESTS. THE PURPOSE OF THIS SYNOPSIS IS TO GAIN KNOWLEDGE OF POTENTIALLY QUALIFIED SOURCES AND THEIR SIZE S (SMALL BUSINESS, LARGE BUSINESS, ETC.). PLEASE DO NOT REQUEST A COPY OF A SOLICITATION, AS ONE DOES NOT EXIST. 1. Purpose.

This is a Sources Sought in support of Market Research being conducted by the United States Air Force to identify potential sources for a contractor to provide comprehensive planned maintenance, continuous wireless condition monitoring, and alignment services for two critical pieces of equipment: Air Conditioning Unit 1 (ACU

1) and Air Conditioning Unit 2 (ACU 2). Both units are located at Edwards Air Force Base, Building 1030, for the 772TS/EWOX. The purpose of this service is to ensure enhanced equipment reliability and prevent costly downtime by shifting from purely schedule-based maintenance to a data-driven model, utilizing a permanent condition monitoring system to trigger specific maintenance actions. The resulting contract will include one (1) base year and four (4) option years. 2. Requirement.

SCOPE OF WORK: The contractor shall provide all necessary labor, hardware, software, and expertise to transition the equipment to a monitored, data-driven maintenance program. The scope encompasses the following: Permanent Condition Monitoring System (Base Year Requirement) Installation & Integration: Supply and install a permanent, wireless condition monitoring system (including all necessary hardware and software) on both ACU 1 and ACU 2. System Capabilities: The system must provide continuous remote monitoring of critical operational parameters (e.g., vibration, temperature) to establish baselines and detect anomalies. Ongoing Monitoring and Data-Driven Maintenance Continuous Monitoring: Provide ongoing remote monitoring and data analysis of the equipment's health parameters. Data-Driven Interventions: Major service actions—such as precision laser shaft alignments (including hot condition alignment for the blower) and bearing replacements shall be performed as-needed based on system triggers and data trends, rather than solely on an annual schedule. Routine Annual Inspection and Preventative Maintenance Component Inspection: Annually inspect foundations, mounting hardware, electrical connections, controls, and shaft couplings. For ACU 1 (Blower), inspect the bearing housing, reservoir, throttle valve, and air filter (providing recommendations). Lubrication: Perform a complete lubrication change on motor and blower bearings in accordance with manufacturer specifications and data indicators. Seal Maintenance: Replace shaft seals on the ACU 1 Blower as needed. Operational Checks: Perform motor amperage checks and overall operational checks, including surge condition checks for the ACU 1 Blower.

DELIVERABLES: The contractor shall provide the following

Get matched to contracts like this daily

Free AI-powered contract matching for your business.