ActiveMonitor
Save

Construct Centralized Emergency Power System

Veterans Affairs (VA)
SDVOSBTBD
$26K – $415K per task order

Informational notice — track for solicitation

This opportunity is not yet open for proposals. Use this time to prepare — engaging early (capability statement, contacting the agency) can position you for the upcoming solicitation.

Quick Brief

The Department of Veterans Affairs is contracting for the construction of a Centralized Emergency Power System at the Robert J. Dole VA Medical Center in Wichita, KS. This project involves installing new generators, constructing distribution networks, and integrating existing facilities into the new system to enhance emergency power capabilities. Key requirements include the installation of HVAC systems, fuel storage tanks, and the construction of a new generator building.

Generated 23d ago

Want to track notices like this?

Get your fit score, win probability, and required capabilities.

Fit Score7/10Consider

Contract Details

Contract Type
TBD
Contract Value
$26K – $415K per task order
IDIQ ceiling: $50M
Similar contracts award $26K to $415K (median $100K, 70,869 awards)
NAICS Codes
Place of Performance
Wichita, KS, USA
Set-Asides
SDVOSB

Qualifications & Eligibility

Set-Aside Category
SDVOSB

Agency & Contact

Contracting Organization

Agency
VETERANS AFFAIRS, DEPARTMENT OF
Sub-Agency
NETWORK CONTRACTING OFFICE (36C255)

Point of Contact

John A. Smith
Contracting Officer
(202) 555-0100

Key Dates

Published1mo ago
Jun 11, 2026
Last Updated1mo ago
Jun 11, 2026
Became Presolicitation1mo ago
Jun 11, 2026
Tracked
Response Duein 8d
Aug 1, 2026
Response Datein 8d
Aug 1, 202614:00

Description

This presolicitation is extended until August 1, 2026 Project 589A7-21-132 Construct Centralized Emergency Power System Robert J. Dole VA Medical Center The Department of Veterans Affairs, Network

Contracting Office (NCO) 15, has a requirement to Construct Centralized Emergency Power System, project number 589A7-21-132, located at the U.S Department of Veterans Affairs, Robert J. Dole VA Medical Center 5500 E Kellogg Dr, Wichita, KS 67218 The following narrative is intended to provide an overview of the

scope of work for the proposed project. PROJECT DESCRIPTION AND SCOPE 1. Purpose of Project The Robert J. Dole VA Medical Center requires the services to Construct Centralized Emergency Power System. T This project will construct a new, centralized emergency power system to enhance the emergency power capabilities of the Robert J. Dole VA Medical Center. This upgrade will support the current facility and future campus expansion of up to 150,000 additional square feet. The project will replace multiple distributed generators with a single, state-of-the-art, medium voltage power generation and distribution facility designed for resilience, security, and operational efficiency. Work will be executed in accordance with the project drawings and specifications, which have been developed by an Architectural-Engineering firm. These documents detail the scope and standards for the work to be performed in addition to any supplemental information provided in this document. 2.

Scope of Work The work includes, but is not limited to, the following: Electrical Centralized Generation: Install three new paralleled 3MW, 12.47kV diesel generators and associated paralleling switchgear to provide reliable N+1 emergency backup power for the campus and future expansions. Distribution Networks: Construct new underground, concrete-encased duct banks for both normal and emergency medium voltage power loops, including new pad-mounted stepdown transformers at each building. Campus Integration: Decommission and remove existing localized life safety generators and fuel tanks, integrating all facilities into the new centralized emergency power system. System Controls and Testing: Provide and connect load bank for generator testing, integrate start signals at all automatic transfer switches, and ensure system delivers emergency power within code-mandated timeframes. Low Voltage & Controls: Install new dedicated low voltage (including fiber optic as necessary) communication duct banks for system controls and tie all security and monitoring equipment back to campus head-end systems. Mechanical Building HVAC: Furnish and install dedicated HVAC systems for temperature regulation of generators, electrical switchgear, and support spaces, including steam heating and DX cooling per VA design standards. Ventilation: Provide appropriately sized air intake/exhaust systems with impact-rated louvers, attenuators, and fans to maintain safe and efficient generator operation. Fuel Oil Storage & Handling: Supply and install two 40,000-gallon double-wall fiberglass underground storage tanks with leak detection, day tank, pump system, and all associated secondary containment piping and trenching to support continuous operation. Civil & Site New Generator Building: Construct a new, blast-rated enclosure (approx. 5,100 GSF) including all utilities, foundations, and architectural finishes per historic and campus standards. Site Utilities: Extend and reroute campus site utilities (including natural gas, domestic water, and steam) as necessary to support the new generator facility. Site Security & Access: Implement new site security fencing, blast protection walls, security gates with dual-authentication entry, and reconfigure drive aisles and parking as required by the VA Physical Security Master Plan. Site Restoration & Stormwater: Re-grade disturbed areas and address all required stormwater management in accordance with local and VA standards, returning the site to full operational capacity at project completion. Multidisciplinary Coordination Architectural and Structural: The scope also requires all architectural and structural work needed to support the electrical and mechanical systems, including building finishes, protective construction, and integration of security features. Communications/Security Systems: Deploy all systems in conformance with VA

requirements and fully coordinate with campus-wide communications, fire alarm, and access control devices. General

Requirements Standards & Compliance: All work must conform to the latest VA, federal, state, and local codes and standards, including but not limited to NFPA, and the VA Physical Security and Resiliency Design Manual (PSRDM). Document Adherence: The full

Get matched to contracts like this daily