The response deadline has passed. Review the details for future reference or to track similar opportunities.
The US Coast Guard is procuring hull inspection and zinc renewal services for the USCGC Donald Horsley. The contractor must conduct an underwater inspection, cleaning, and renewal of zinc anodes while the vessel is moored, with specific requirements for trained personnel and adherence to maintenance procedures.
The contractor will perform underwater hull inspection, cleaning, and zinc renewal for the USCGC Donald Horsley.
52000QR260023810 USCGC DONALD HORSLEY HULL INSPECTION AND ZINC RENEWAL INTENT: This work item describes the
requirements for the Contractor to conduct an inspection and cleaning of the vessel’s U/W body and renew U/W zinc anodes while the vessel is moored pier side. Affected surfaces or components include, but are not limited to the following: • U/W hull plating. • U/W body coating system. • Transducer(s)/sonar dome. • Drive Systems • Appendages • Cathodic Protection This is a combined for commercial items prepared in accordance with the format in FAR Subpart 12.6 as supplemented with additional information in this notice. This solicitation is issued as a Request for Quote Number 52000QR260023810 USCGC DONALD HORSLEY HULL INSPECTION AND ZINC RENEWAL This procurement will be processed in accordance with FAR Part 12. The North American Industry System (NAICS) is 336611 - Ship Building and Repairing. This is total small business set aside; all responsible small business sources may submit proposals that will be considered. This is issued pursuant to FAR 13.106-1(b), and the resultant purchase order will be awarded on a firm-fixed price basis using simplified acquisition procedures in accordance with FAR 13. THE UNITED STATED COAST GUARD SURFACE FORCE LOGISTICS CENTER REQUEST THE CONTRACTORS TO PROVIDE
PRICING FOR THE FOLLOWING REQUIREMENT: The contractor shall provide 52000QR260023810 USCGC DONALD HORSLEY HULL INSPECTION AND ZINC RENEWAL Statement of Work (SOW) For Underwater Hull Inspect, Clean & Zinc Renewal 1.
Background and Current Observed Issues CGC DONALD HORSLEY is requesting underwater hull inspection, cleaning and zinc renewal. 2. REFERENCES CG MPC B10015.D, UNDERWATER BODY (DIVER), INSP/CLN CG MPC B10018.D, UNDERWATER ZINC ANODES, REPLACE 3.
REQUIREMENTS Entity completing the work must have trained personnel. The diver must have a dive tender aboard the vessel during dive operations. Hull must be thoroughly cleaned IAW MPC B10015.D and all pre& post cleaning forms must be completed. Zincs must be renewed IAW MPC B10018.D. There are 12 additional stern tube zincs not identified in the current B10018.D maintenance procedure card. 4.
PERIOD OF PERFORMANCE This maintenance must be completed between
Get matched to contracts like this daily
Free AI-powered contract matching for your business.