Closed
Save

Nikon AX R Spatial Array Confocal Microscope System

Health & Human Services (HHS) > NIH > ODSol: 75N98026R00105
SBTBD
est. $250K – $600K

This opportunity is closed

The response deadline has passed. Review the details for future reference or to track similar opportunities.

Quick Brief

The Department of Health and Human Services is conducting a market survey to identify qualified small businesses capable of providing a Nikon AX R with Nikon Spatial Array Confocal (NSPARC) Microscope Detector Technology System. The system will be used by the National Institutes of Health for ex vivo imaging of mouse cochleae to study dendritic function and signaling. Key requirements include an upright microscope configuration, single-photon sensitivity, and compatibility with patch-clamp electrophysiology.

Generated 36d ago

Scope & Requirements

Procurement of a high-resolution confocal microscope system with SPPC array detector technology for live imaging of ex vivo cochlear preparations and simultaneous electrophysiology.

Deliverables

  • Nikon AX R with Nikon Spatial Array Confocal (NSPARC) Microscope Detector Technology System

Evaluation Criteria

  1. Technical capability
  2. Availability

Attachments

No files on SAM.gov

This listing does not include downloadable attachments. The solicitation details may be in the description below.

Verify on SAM.gov

Contract Details

Contract Type
TBD
Estimated Value
est. $250K – $600K
Similar contracts award $14K to $90K (median $33K, 26,980 awards)Above typical range
NAICS Codes
Set-Asides
SB

Qualifications & Eligibility

Set-Aside Category
8(a)

Agency & Contact

Contracting Organization

Agency
HEALTH AND HUMAN SERVICES, DEPARTMENT OF
Sub-Agency
National Institutes of Health
Office
OD

Point of Contact

John A. Smith
Contracting Officer
(202) 555-0100

Key Dates

Published1mo ago
Jun 17, 2026
Became Solicitation1mo ago
Jun 18, 2026
Tracked
Last Updated1mo ago
Jun 19, 2026
Sought Response Date1mo ago
Jun 24, 20265:00 PM EDT
Response Due1mo ago
Jun 24, 2026

Description

The National Institutes of Health (NIH), (OD) is conducting a market survey to determine the availability and technical capability of qualified small businesses, including 8(a) small businesses, small, disadvantaged businesses, woman-owned small businesses, service-disabled veteran-owned small businesses or HUBZone small businesses capable of providing a new Brand name or equal to Nikon AX R with Nikon Spatial Array Confocal (NSPARC) Microscope Detector Technology System. Description: Planned experiments involve ex vivo imaging of dissected mouse cochleae to study dendritic function and signaling in olivocochlear efferent neurons. Experiments will include calcium imaging, neurotransmitter imaging, genetically encoded voltage indicator imaging, and simultaneous patch-clamp electrophysiology. The neuronal dendrites under study are approximately 1 µm in diameter, produce dim fluorescent signals, and require high-speed imaging with high signal-to-noise ratio. The microscope system must provide enhanced fluorescence detection sensitivity to enable reliable detection of weak fluorescent signals while minimizing photobleaching and phototoxicity. The system must be configured as an upright microscope to accommodate ex vivo cochlear preparations, high-numerical-aperture water-dipping

objectives, live pharmacological manipulations during experiments, and integration with patch-clamp electrophysiology equipment. Product Specifications/Features/Salient Characteristics Required Minimum Specifications: Required Specifications for Confocal Imaging System: Microscope configuration -Upright microscope configuration (FN1 compatible) Detector technology -25-element SPPC (Single Pixel Photon Counter) array detector Detector sensitivity - Single-photon sensitivity Detector noise - Ultra-low-noise detector array Signal-to-noise ratio - Improved SNR compared with conventional PMT and GaAsP detectors Imaging application - Live imaging of ex vivo cochlear preparations

Objectives -Compatible with high-numerical-aperture (1.0 N.A.) water-dipping

objectives Patch-clamp integration -Compatible with simultaneous electrophysiology experiments Drug application -Supports live pharmacological manipulation during imaging Time-lapse imaging -Required for monitoring dynamic neuronal activity Calcium imaging -Required Neurotransmitter imaging -Required Voltage imaging -Required Low-light imaging - Required for dim genetically encoded indicators Photobleaching reduction - Improved signal collection allowing lower excitation power Phototoxicity reduction -Required for extended live imaging experiments Lateral resolution -Approximately 100 nm super-resolution capability Axial resolution - Approximately 300 nm super-resolution capability Resonant imaging -Compatible with AX R resonant scanner Pixel dwell time -As short as 200 nanoseconds Maximum resonant image size - Up to 2048 × 2048 pixels High-speed acquisition - Up to 720 fps at 2048 × 16 pixels Large field of view -FN25 optical system Software compatibility -Nikon NIS-Elements software compatibility required Existing workflow compatibility -Compatible with existing Nikon imaging workflows and user expertise User training burden - No significant additional training compared to existing Nikon systems Collaborative research support - Capable of supporting NIH and extramural collaborations Interested firms with the capability of providing all the required items shall submit a capability statement to assist the Government in determining in accordance with the Federal Acquisition Regulation 19.104-1. The intended procurement will be classified under North American Industrial (NAICS) code 334516 with a size standard of 1000e. All respondents are required to identify their firm’s size and type of business. Interested firms responding to this market survey must provide (a) capability statement demonstrating their experience, skills and capability to fulfill the Government’s

requirements for the above. The capability statement shall be in sufficient enough details so that the Government can determine the experience and capability of your firm to provide the items above. Offers must also be accompanied by descriptive literature, delivery timeframe, warranties and other information that demonstrates that the offer meets all the foregoing

requirements. Capability statements must include the name and telephone number, and email address of a

Get matched to contracts like this daily

Free AI-powered contract matching for your business.