The Department of Veterans Affairs is seeking a contractor to provide a one-year service agreement for preventative maintenance on the Reverse Osmosis/Deionizing System at the Huntington VAMC. Key requirements include monthly, quarterly, and annual maintenance tasks, as well as prompt support for any mechanical issues that arise with the system to ensure compliance with VA standards.
F103--New Base + 4 Service Agreement for SPS RO_DI Water System Sources Sought F103--New Base + 4 Service Agreement for SPS RO_DI Water System Sources Sought Sought VETERANS AFFAIRS, DEPARTMENT OF VETERANS AFFAIRS, DEPARTMENT OF -NETWORK CONTRACT (36C245) NVIRONMENTAL SYSTEMS PROTECTION- WATER QUALITY SUPPORT pply and Irrigation Systems
Place of Performance Department of Veterans Affairs Huntington VAMC STATEMENT OF WORK PART A GENERAL INFORMATION A.1 INTRODUCTION The VAMC located at 1540 Spring Valley Drive, Huntington WV, 25704 has a requirement for a 1-year contract to perform preventative maintenance on the Reverse Osmosis/Deionizing System in Sterile Processing. A.2
BACKGROUND The VAMC has a need to have this work performed so this machine continues to perform properly and ensure bacteria does not grow within the system. A.3
SCOPE OF WORK Vendor will provide all parts, labor, equipment, material, and supervision to perform the work as listed below. STATEMENT OF WORK PART B WORK
REQUIREMENTS B.1 Tasks to be accomplished: Perform Monthly Perform Preventive Maintenance Procedure (includes items such as checking system flow, chemistry, and pressure checks, maintaining the anti-scalant pump and solution tank, and updating the information tags with the most recent dates) Replace ChlorPlus Carbon Filter Cartridge, 1 Micron, 2-1/2" x 20" DOE (For Chloramines) install (2) monthly. Replace Filter Cartridge, 50 Micron prefilter/5 micro post filter (nominal), 4-1/2" x 20", Depth, Qty. 1(1) per month. Perform Quarterly DI Regeneration Certificate, Ultra Pure, 1/2 cu. ft. Replace (2) quarterly. Perform Annually Replace Filter Cartridges, Absolute Endotoxin, 0.2 Micron, 2-1/2" x 20", 222, Pall, total Quantity of 4 filters. Replace ultraviolet unit bulb (VIQUA Model#VP600M), Quantity 1 bulb. Replace Peracidin Disinfectant Concentrate, (4) 1 qt. Containers. Provide Residual Chlorine Test Strips, (6) Bottles of 100 Provide Renal Check, Residual Peroxide Test Strips (Low Level), (6) Bottles of 100 During the contract, the contractor shall support/resolve all issues with the RO/DI system to ensure and maintain passing test results required by VA Sterile Processing Department. Additionally, any RO/DI system mechanical issues will require prompt assistance in triage so that the vendor can notify VA personnel if the issue is out of contract scope. If the issue is out of scope, VA will work to have a credit card order placed from the quote provided or submit for another contract to complete required services with COR oversight. STATEMENT OF WORK PART C SUPPORTING INFORMATION C.1
Place of Performance The VAMC located at 1540 Spring Valley Drive, Huntington WV 25704. C.2