Self-Contained Breathing Apparatus Preventive Maintenance

Department of Defense (DoD) > U.S. ArmySol: PANMCC26P0000037013
8(a)SDVOSBWOSBTBD
$8K – $57K per task order

This opportunity is closed

The response deadline has passed. Review the details for future reference or to track similar opportunities.

Quick Brief

The Department of Defense is seeking services for the preventive maintenance of Self-Contained Breathing Apparatus (SCBA) units and masks for the Garrison Yuma Proving Ground Fire Department at the United States Army Yuma Proving Ground, AZ. The contractor will be responsible for annual inspections, maintenance, and minor repairs, ensuring compliance with various safety standards and manufacturer specifications. Technicians must hold specific certifications and all work must be documented and meet established pass criteria.

Generated 37d ago

Scope & Requirements

The contractor will perform preventive maintenance on SCBA units and masks, including inspections, minor repairs, and compliance with safety standards.

Contract Details

Contract Type
TBD
Contract Value
$8K – $57K per task order
IDIQ ceiling: $12.5M
Similar contracts award $8K to $57K (median $21K, 16,588 awards)
Period of Performance
2026-10-01 through 2031-09-30
NAICS Codes
Place of Performance
Yuma Proving Ground, AZ, USA
Set-Asides
8(a), SDVOSB, WOSB

Qualifications & Eligibility

Certifications
  • MSA CARE Comprehensive Training
  • MSA CARE Facility certification

Agency & Contact

Contracting Organization

Agency
DEPT OF DEFENSE
Sub-Agency
DEPT OF THE ARMY
Office
AMC ACCMISSION INSTALLATION CONTRACTING COMMAND418TH CSB -YUMA PROV GRD

Point of Contact

John A. Smith
Contracting Officer
(202) 555-0100

Key Dates

Published1mo ago
Jun 16, 2026
Became Solicitation1mo ago
Jun 16, 2026
Tracked
Last Updated1mo ago
Jun 18, 2026
Response Date29d ago
Jun 26, 202617:00
Response Due28d ago
Jun 27, 2026

Description

The Mission and Installation Contracting Command (MICC), Yuma Proving Ground (MICC-YPG), is currently conducting market research to attempt to bolster government and industry coordination and partnership in supporting the Garrison Yuma Proving Ground Fire Department (YPGFD) at United States Army Yuma Proving Ground (USAYPG), AZ. This RFI is being issued to inquire about the maintenance and services for Self-Contained Breathing Apparatus (SCBA) assemblies and masks located at USAYPG, AZ. The service requirement covers the annual inspection, maintenance, and minor repairs of SCBA units and masks located at USAYPG, AZ, for the Garrison YPGFD. All work shall be performed in accordance with the publications referenced in the Performance Work Statement (PWS), including all applicable Mine Safety Appliance (MSA) manufacturer recommendations and specifications, as well as OSHA 1910.334, OSHA 1910.156, NFPA 1500, NFPA 1852, NFPA 1981, and NFPA 1989. All technicians performing work under this requirement must hold MSA CARE Comprehensive Training certifications. These certifications must be current and maintained throughout the duration of the contract. In addition, the contractor must possess a valid MSA CARE Facility certification and provide proof of this certification during the solicitation phase. All certifications must remain compliant with current MSA

requirements. The technician shall adjust each component in accordance with the manufacturer’s specifications. A total of 60 SCBA assemblies and 45 masks will be tested. Minor repairs include the replacement of o‑rings, grease, silicone, and other rubber components routinely consumed during inspection, adjustment, and testing. Masks must successfully pass a visual inspection, leakage test, and exhalation pressure test. Individual test results shall be documented and submitted to the COR. MSA G1 airpacks will be inspected and tested using Posi3 USB or an equivalent system. The testing unit must be calibrated prior to beginning any testing. Testing will include, but is not limited to: Verification of all serial numbers and IDs associated with each airpack Visual inspection of the backframe/harness, low‑pressure warning system, and hoses Functional tests, including: Static facepiece pressure Static medium pressure Medium pressure creep First‑breath activation High‑pressure leakage Bypass pressure Alarm activation pressure testing of the G1 4500 bell (33%), including ringdown results Gauge accuracy testing at 1000 PSI, 2000 PSI, and 3000 PSI G1 4500 HUD testing at 33% and 50% Any item that fails any portion of the testing must be repaired and retested until all results meet “Pass” criteria. SCBA Maintenance