Fire Suppression Backflow Preventer Installation and Maintenance

Department of Defense (DoD)Sol: PANNGB26P0000038507
SB
$13K – $123K per task order

This opportunity is closed

The response deadline has passed. Review the details for future reference or to track similar opportunities.

Contract Details

Contract Value
$13K – $123K per task order
IDIQ ceiling: $19M
Similar contracts award $13K to $123K (median $35K, 14,626 awards)
NAICS Codes
Set-Asides
SB

Agency & Contact

Contracting Organization

Agency
DEPT OF DEFENSE

Point of Contact

John A. Smith
Contracting Officer
(202) 555-0100

Key Dates

Published16d ago
Jul 9, 2026
Became Award Notice15d ago
Jul 9, 2026
Tracked
Last Updated14d ago
Jul 10, 2026
Response Due4d ago
Jul 20, 2026

Description

This is a SOURCES SOUGHT ANNOUNCEMENT ONLY. The purpose of this sources sought is for market research to gain knowledge of potential sources for future needs including interested small business sources. This notice is for planning purposes only. All interested parties should respond. Kansas Air National Guard, McConnell AFB will soon be soliciting for a project for Backflow Preventer Upgrades. The work shall consist of removal of the five backflow preventer systems varying in size and purpose and the installation of five new backflow preventer systems, replacing the existing systems. The contractor will be responsible for removal, proper sizing, connections, installation of the new backflow preventers, testing/certifying, and when complete there will be no defects nor leaks. The project needs to include the following: Building 33, Southwest Bay – 6-inch diameter Backflow Preventer System for Fire Suppression Remove the existing 6-inch diameter Fire Suppression Backflow Prevention System. Install a new 6-inch diameter Fire Suppression Backflow Prevention System. Testing of the newly installed 6-inch diameter Fire Suppression Backflow Prevention System by a certified installer/tester that meets the

requirements set up by the board of appeals of plumbers and gas fitters of the city of Wichita & Sedwick County. Upon completion of the certification of the Backflow Prevention System, provide the 184 CES/CEO with the following: Backflow Prevention System’s Installation Date Backflow Prevention System’s Manufacture Backflow Prevention System’s Model Backflow Prevention System’s Serial Number Backflow Prevention System’s Rebuild Kit Specifications Backflow Prevention System’s Building 44, Room 122, South wall – 4-inch diameter Backflow Preventer System for Fire Suppression and Double Check Valve Remove the existing 4-inch diameter Fire Suppression and Double Check Valve Backflow Prevention System. Install a new 4-inch diameter Fire Suppression and Double Check Valve Backflow Prevention System. Testing of the newly installed 4-inch diameter Fire Suppression and Double Check Valve Backflow Prevention System by a certified installer/tester that meets the

requirements set up by the board of appeals of plumbers and gas fitters of the city of Wichita & Sedwick County. Upon completion of the certification of the Backflow Prevention System, provide the 184 CES/CEO with the following: Backflow Prevention System’s Installation Date Backflow Prevention System’s Manufacture Backflow Prevention System’s Model Backflow Prevention System’s Serial Number Backflow Prevention System’s Rebuild Kit Specifications Backflow Prevention System’s Building 44, Room 118, Interior, Southeast wall – 1-inch diameter Backflow Preventer System for Boiler Makeup Remove the existing 1-inch diameter Boiler Makeup Backflow Prevention System. Install a new 1-inch diameter Boiler Makeup Backflow Prevention System. Testing of the newly installed 1-inch diameter Boiler Makeup Backflow Prevention System by a certified installer/tester that meets the

requirements set up by the board of appeals of plumbers and gas fitters of the city of Wichita & Sedwick County. Upon completion of the certification of the Backflow Prevention System, provide the 184 CES/CEO with the following: Backflow Prevention System’s Installation Date Backflow Prevention System’s Manufacture Backflow Prevention System’s Model Backflow Prevention System’s Serial Number Backflow Prevention System’s Rebuild Kit Specifications Backflow Prevention System’s Building 48, Room 107, East wall – 4-inch diameter Backflow Preventer System for Fire Suppression Remove the existing 4-inch diameter Fire Suppression Backflow Prevention System. Install a new 4-inch diameter Fire Suppression Backflow Prevention System. Testing of the newly installed 4-inch diameter Fire Suppression Backflow Prevention System by a certified installer/tester that meets the

requirements set up by the board of appeals of plumbers and gas fitters of the city of Wichita & Sedwick County. Upon completion of the certification of the Backflow Prevention System, provide the 184 CES/CEO with the following: Backflow Prevention System’s Installation Date Backflow Prevention System’s Manufacture Backflow Prevention System’s Model Backflow Prevention System’s Serial Number Backflow Prevention System’s Rebuild Kit Specifications Backflow Prevention System’s Building 65, Room 154, Interior, South – 2.5-inch diameter Backflow Preventer System for domestic water Remove the existing 2.5-inch diameter domestic water Backflow Prevention System. Install a new 2.5-inch diameter domestic water Backflow Prevention System. Testing of the newly installed 2.5-inch diameter domestic water Backflow Prevention System by a certified installer/tester that meets the

requirements set up by the board of appeals of plumbers and gas fitters of the city of Wichita & Sedwick County. Upon completion of the certification of the Backflow Prevention System, provide the 184 CES/CEO with the following: Backflow Prevention System’s Installation Date Backflow Prevention System’s Manufacture Backflow Prevention System’s Model Backflow Prevention System’s Serial Number Backflow Prevention System’s Rebuild Kit Specifications Backflow Prevention System’s For this requirement, the small business size standard is $19 million for NAICS 238220. In the event small business In the event small business contractors are not avaialble for adequate competition for this project, it may be advertised as unrestricted. Please advise on your capabilities and or past perfromance in terms of the project requested and respond with a completed sources sought response form. Include the following email subject line "Fire Suppression Backfow Preventer Upgrades" when emailing [email protected]. Use the same address if you have additional