Mess Deck and Communications Room Electrical Work

Homeland Security (DHS) > U.S. Coast Guard
FFP
est. $15K – $45K
Quick Brief

The Department of Homeland Security is procuring electrical correction and installation services for the USCG Station Bodega Bay. The contractor must resolve hazardous mis-wired conditions and install new dedicated convenience outlet circuits for the Watch Room, Mess Deck, Galley, and COM Room. Key requirements include eliminating recurring breaker trips and ensuring code-compliant electrical service for mission-essential equipment.

Generated 10d ago

Can you win this contract?

Get your fit score, win probability, and required capabilities.

Fit Score7/10Consider

Scope & Requirements

Correct hazardous electrical conditions and install new dedicated convenience outlet circuits in the Watch Room, Mess Deck, Galley, and COM Room to ensure code compliance and safety.

Deliverables

  • Corrected electrical wiring
  • New dedicated convenience outlet circuits

Contract Details

Contract Typei
FFP
Estimated Value
est. $15K – $45K
Similar contracts award $13K to $139K (median $39K, 9,267 awards)Within typical range
NAICS Codes
Place of Performance
Bodega Bay, CA, USA

Qualifications & Eligibility

Set-Aside Category
Total Small Business Set-Aside

Agency & Contact

Contracting Organization

Agency
HOMELAND SECURITY, DEPARTMENT OF
Sub-Agency
US COAST GUARD

Point of Contact

John A. Smith
Contracting Officer
(202) 555-0100

Key Dates

Site Visit Day 119d ago
Jul 6, 2026
Site Visit Day 218d ago
Jul 7, 2026
Published12d ago
Jul 13, 2026
Last Updated12d ago
Jul 13, 2026
Became Solicitation11d ago
Jul 13, 2026
Tracked
Solicitation Closing Date8d ago
Jul 17, 2026
Response Duein 3d
Jul 28, 2026

Description

the Statement of Work. See the Amended Solicitation document attachment. The solicitation closing date is changed to July 17, 2026. The Solicitation is for a contractor to furnish all labor, materials, tools, equipment, supervision, and incidentals necessary to correct hazardous electrical conditions and install new dedicated convenience outlet circuits serving the Watch Room, Mess Deck, Galley, COM Room, and associated attic spaces. Work should eliminate existing mis-wired conditions, resolve recurring breaker trips, and provide safe, code-compliant electrical service for mission-essential equipment. The facility is experiencing repeated circuit breaker trips and loss of power due to improperly wired and overloaded circuits originating from a junction box located in the Mess Deck CMU wall. Investigation revealed unsafe voltage conditions, including 240V supplied to 110V receptacles, absence of neutral and grounding conductors, evidence of arcing, and shared circuits supplying lighting and convenience outlets. Immediate temporary disconnect actions were taken for safety; permanent corrective action is required. Offerors or quoters are urged and expected to inspect the site where the work will be performed. Site visits will be available on Monday, July 6, 2026 and Tuesday, July 7, 2026. To coordinate please reach out to: MK1 Joshua Florez, 707-875-3596, or 760-702-2343. Anthony Ciurlino Alternative

Point of Contact Victor Regalado Contracting , BUILDING 42 (No Street Address

2) ALAMEDA, CA 94501 USA to this opportunity. Amended Solicitation.pdf USCG Station Bodega Bay Electrical_SAM.gov Solicitation.docx (deleted)