Closed
Save

Electrical Lead Assembly

Department of Defense (DoD)Sol: N0010426RFC57
FFP
$59K

This opportunity is closed

The response deadline has passed. Review the details for future reference or to track similar opportunities.

Quick Brief

The Department of Defense is procuring lead assemblies for communication equipment to support the Navy's weapon systems. Key requirements include compliance with various quality standards, submission of certification data, and adherence to a specified delivery schedule. The contract will be a fixed-price type with a focus on national defense use.

Generated 32d ago

Contract Details

Contract Typei
FFP
Contract Value
$59K
Similar contracts award $922 to $13K (median $4K, 15,901 awards)Above typical range
NAICS Codes
Place of Performance
Mechanicsburg, ND, USA

Agency & Contact

Contracting Organization

Agency
DEPT OF DEFENSE

Point of Contact

John A. Smith
Contracting Officer
(202) 555-0100

Key Dates

Published1mo ago
Jun 22, 2026
Became Solicitation1mo ago
Jun 22, 2026
Tracked
Last Updated1mo ago
Jun 24, 2026
Response Due14d ago
Jul 10, 2026

Description

|4|N743.49|WVE|771-229-0573|[email protected]| ITEM UNIQUE IDENTIFICATION AND VALUATION (JAN 2023)|19|||||||||||||||||||| HIGHER-LEVEL CONTRACT QUALITY REQUIREMENT (DEC 2014)|1|See specification sections C and E.| INSPECTION OF SUPPLIES--FIXED-PRICE (AUG 1996)|2||| STOP-WORK ORDER (AUG 1989)|1|| GENERAL INFORMATION-FOB-DESTINATION|1|B| WIDE AREA WORKFLOW PAYMENT INSTRUCTIONS (JAN 2023)|16|Stand-Alone Receiving Report - Certifications Combo - Receiving Report & Invoice - Material |N/A|TBD|N00104|TBD|N39040 - Certifications, S4306A - Material |N50286|TBD|133.2|N/A|N/A|N39040 - Certifications |N/A |N/A|SEE DD FORM 1423 |[email protected] [email protected]| NAVY USE OF ABILITYONE SUPPORT CONTRACTOR - RELEASE OF OFFEROR INFORMATION (3-18))|1|| MANDATORY USE OF WORKFLOW PRO (WFP) MOD ASSIST MODULE|1|| VALUE ENGINEERING (JUN 2020)|3|||| INTEGRITY OF UNIT PRICES (NOV 2021)|1|| EQUAL OPPORTUNITY FOR VETERANS (DEV 2026-O0040)(FEB 2026)|4||||| WARRANTY OF SUPPLIES OF A NONCOMPLEX NATURE (JUNE 2003)|6|One year from date of delivery.|One year from date of delivery.||||| SMALL BUSINESS SUBCONTRACTING PLAN (DEV 2026-O0037)(FEB 2026)|4||||| EQUAL OPPORTUNITY FOR WORKERS WITH DISABILITIES (DEV 2026-O0040)(FEB 2026)|4||||| TRANSPORTATION OF SUPPLIES BY SEA (OCT 2024)|2||| FIRST ARTICLE APPROVAL--GOVERNMENT TESTING (DEV 2026-O0042)(FEB 2026)|7|One|0001AC|30|N39040|270|X|| BUY AMERICAN-FREE TRADE AGREEMENTS-BALANCE OF PAYMENTS PROGRAM-BASIC (FEB 2024)|11|||||||||||| SMALL BUSINESS SUBCONTRACTING PLAN (DOD CONTRACTS)-BASIC (DEV 2026-O0037)(FEB 2026))|2||| WARRANTY OF DATA-BASIC (DEVIATION 2026-O0035) (FEB 2026)|2||| CONTRACTOR PURCHASING SYSTEM ADMINISTRATION-BASIC (DEVIATION 2026-O0015)|1|| SECURITY PROHIBITIONS AND EXCLUSIONS (CLASS DEVIATION 2026-O0025)(FEB 2026)|7|||||||| PERFORMANCE-BASED PAYMENTS (APR 2012)|1|| LIST OF AWARD

ATTACHMENTS|5|||||| BUY AMERICAN-FREE TRADE AGREEMENTS-BALANCE OF PAYMENTS PROGRAM CERTIFICATE-BASIC (FEB 2024))|5|||||| BUY AMERICAN-BALANCE OF PAYMENTS PROGRAM CERTIFICATE-BASIC (FEB 2024)|1|| ALTERNATE A, ANNUAL REPRESENTATIONS AND CERTIFICATIONS (DEVIATION 2026-O0043)(FEB 2026))|13|||||||||||||| ROYALTY INFORMATION (APR 1984)|1|| COST ACCOUNTING STANDARDS NOTICES AND CERTIFICATION (DEV 2026-O0006)(FEB 2026)|1||

INSTRUCTIONS TO OFFERORS -- COMPETITIVE ACQUISITION (DEV 2026-O0048)(MAR 2026)|2||| ALTERATIONS IN SOLICITATION (APR 1984)|3|||| NOTICE OF PRIORITY RATING FOR NATIONAL DEFENSE, EMERGENCY PERPARDENESS, AND ENRGY PROGAM USE (APRIL 2008))|2||X| ONLY ONE OFFER (DEVIATION 2026-O0048)(MAR 2026)|1|| EVALUATION OF FIRST ARTICLE TESTING|3|X|$59K|| This amendment is issued to extend the closing date. \ 1.DD1423 Data Item A001 (Inspection and Test Plan) may be waived if already on file at NAVSUP WSS Mechanicsburg. 2. Portsmouth NSY's DODAAC has changed from N00102 to N50286. Any reference toN00102 within this order should be updated to N50286. 3. The following proposed delivery schedule applies: Submission of Certification Data CDRLs will be on or before 20 days prior toscheduled delivery. FAT REPORT 180 DAYS AFTER APPROVAL OF PR LT APPROVAL OF FAT REPORT 60 DAYS AFTER RECEIPT PNSY review/acceptance of Certification CDRLs 6 workingdays after receipt of Certification DD 1423 CDRLs. Final delivery of materialwill be on or before 365 days after effective date of the resulting contract. 4. Any contract awarded as a result of this solicitation will be "DO" rated order; "DO" rated order certified for national defense use under the DefensePriorities and Allocations System (DPAS). 5. If drawings are included in the solicitation, access needs to be requested on the individual solicitation page on Contracts Opportunities on theGovernment's SAM.gov website. After requesting access, send an email to thePrimary POC listed on the solicitation. 6. This solicitation requires First Article Testing. See FAR 52.209-4 First Article Approval - Government Testing 7. The complete RFP package must be signed and returned prior to the closing date. Emailed or faxed proposals are acceptable. NECO quotes will NOT beaccepted and will be determined non-responsive. \ 1. SCOPE 1.1 The material covered in this contract/purchase order will be used in a crucial shipboard system. The use of incorrect or defective material would create a high probability of failure resulting in serious personnel injury, loss of life, loss of vital shipboard systems, or loss of the ship itself. Therefore, the material has been designated as SPECIAL EMPHASIS material (Level I, Scope of Certification, or Quality Assured) and special control procedures are invoked to ensure receipt of correct material. 2. APPLICABLE DOCUMENTS 2.1 Order of Precedence - In the event of a conflict between the text of this contract/purchase order and the references and/or drawings cited herein, the text of this contract/purchase order must take precedence. Nothing in this contract/purchase order, however, must supersede applicable laws and regulations unless a specific exemption has been obtained. 2.2 Applicable Documents - The document(s) listed below form a part of this contract/purchase order including modifications or exclusions. 2.2.1 Specification Revisions - The specification revisions listed under "Documents References" below are the preferred revision. Older and/or newer r evisions are acceptable when listed within Contract Support Library Reference Number CSD155 in ECDS (Electric Contractor Data Submission) at: ht tps://register.nslc.navy.mil/. This is to allow Contractors to use certain acceptable older specification revisions to purge their existing stock of material certified to those older revisions or to use newer specification revisions when material is certified to newly released revisions,without requiring the submittal of waiver/deviation requests for each specification revision on every contract. Revisions of specifications reflecting editorial and/or re-approval (e.g. E2009, R2014, etc.) are considered inconsequential, but are acceptable when their revisions are listedwithin CSD155 or elsewhere within this contract. 2.2.2 "Document References" listed below must be obtained by the Contractor. Ordering information is included as an attachment to this contract/purchase order. DRAWING DATA=CPG1022 |96169| F| |D|0001 | F|49998|0030132 DRAWING DATA=CPG1022 |96169| F| |D|0002 | F|49998|0021064 DRAWING DATA=CPG1022 |96169| F| |D|0003 | F|49998|0022286 DRAWING DATA=CPG1022 |96169| F| |D|0004 | F|49998|0021419 DRAWING DATA=CPG1022 |96169| F| |D|0005 | F|49998|0022582 DRAWING DATA=CPG1022 |96169| F| |D|0006 | F|49998|0019811 DRAWING DATA=CPG1022 |96169| F| |D|0007 | F|49998|0022652 DRAWING DATA=CPG1022 |96169| F| |D|0008 | F|49998|0011258 DRAWING DATA=CPG1022 |96169| F| |D|0009 | F|49998|0023824 DRAWING DATA=CPG1022 |96169| F| |D|0010 | F|49998|0020856 DRAWING DATA=CPG1022 |96169| F| |D|0011 | F|49998|0014477 DRAWING DATA=CPG1022 |96169| F| |D|0012 | F|49998|0008560 DRAWING DATA=CPG1022 |96169| F| |D|0013 | F|49998|0018011 DRAWING DATA=CPG1022 |96169| F| |D|0014 | F|49998|0025103 DRAWING DATA=CPG1022 |96169| F| |D|0015 | F|49998|0023546 DRAWING DATA=CPG1022 |96169| F| |D|0016 | F|49998|0020347 DRAWING DATA=CPG1022 |96169| F| |D|0017 | F|49998|0025199 DRAWING DATA=CPG1022 |96169| F| |D|0018 | F|49998|0045572 DRAWING DATA=CPG1022 |96169| F| |D|0019 | F|49998|0040276 DRAWING DATA=CPG1022 |96169| F| |D|0020 | F|49998|0039212 DRAWING DATA=CPG1022 |96169| F| |D|0021 | F|49998|0030139 DRAWING DATA=CPG1022 |96169| F| |D|0022 | F|49998|0037282 DRAWING DATA=CPG1022 |96169| F| |D|0023 | F|49998|0033419 DRAWING DATA=CPG1022 |96169| F| |D|0024 | F|49998|0046612 DRAWING DATA=CPG1022 |96169| F| |D|0025 | F|49998|0042207 DRAWING DATA=CPG1022 |96169| F| |D|0026 | F|49998|0045002 DRAWING DATA=CPG1022 |96169| F| |D|0027 | F|49998|0009713 DRAWING DATA=CPG1022 |96169| F| |D|0028 | F|49998|0046354 DRAWING DATA=CPG1022 |96169| F| |D|0029 | F|49998|0005500 DRAWING DATA=CPG1022 |96169| F| |D|0030 | F|49998|0016659 DRAWING DATA=CPG1022 |96169| F| |D|0031 | F|49998|0041132 DRAWING DATA=CPG1022 |96169| F| |D|0032 | F|49998|0014803 DRAWING DATA=CPG1022 |96169| F| |D|0033 | F|49998|0013312 DRAWING DATA=CPG1022 |96169| F| |D|0034 | F|49998|0030085 DRAWING DATA=CPG1022 |96169| F| |D|0035 | F|49998|0031585 DRAWING DATA=CPG1022 |96169| F| |D|0036 | F|49998|0031527 DRAWING DATA=CPG1022 |96169| F| |D|0037 | F|49998|0012406 DRAWING DATA=CPG1022 |96169| F| |D|0038 | F|49998|0046896 DRAWING DATA=CPG1022 |96169| F| |D|0039 | F|49998|0010039 DRAWING DATA=CPG1022 |96169| F| |D|0040 | F|49998|0056377 DRAWING DATA=CPG1022 |96169| F| |D|0041 | F|49998|0005432 DRAWING DATA=CPG1022 |96169| F| |D|0042 | F|49998|0048047 DRAWING DATA=CPG1022 |96169| F| |D|0043 | F|49998|0052300 DRAWING DATA=CPG1022 |96169| F| |D|0044 | F|49998|0024276 DRAWING DATA=CPG1022 |96169| F| |D|0045 | F|49998|0034480 DRAWING DATA=CPG1022 |96169| F| |D|0046 | F|49998|0026803 DRAWING DATA=CPG1022 |96169| F| |D|0047 | F|49998|0012965 DRAWING DATA=CPG1022 |96169| F| |D|0048 | F|49998|0013581 DRAWING DATA=CPG1022 |96169| F| |D|0049 | F|49998|0010520 DRAWING DATA=CPG1022 |96169| F| |D|0050 | F|49998|0010755 DRAWING DATA=CPG1022 |96169| F| |D|0051 | F|49998|0018605 DRAWING DATA=CPG1022 |96169| F| |D|0052 | F|49998|0009701 DRAWING DATA=CPG1022 |96169| F| |D|0053 | F|49998|0024802 DRAWING DATA=CPG1022 |96169| F| |D|0054 | F|49998|0032131 DRAWING DATA=CPG1022 |96169| F| |D|0055 | F|49998|0014331 DRAWING DATA=CPG1022 |96169| F| |D|0056 | F|49998|0010587 DRAWING DATA=CPG1022 |96169| F| |D|0057 | F|49998|0015026 DRAWING DATA=CPG1022-1 |96169| D| |D|0000.A | D|49998|0074948 DRAWING DATA=CPG1022-1 |96169| D| |D|0000.B | C|49998|0129832 DRAWING DATA=CPG1022-1 |96169| D| |D|0000.C | D|49998|0016731 DRAWING DATA=CPG1022-1 |96169| D| |D|0001 | D|49998|0095662 DRAWING DATA=CPG1022-1 |96169| D| |D|0002 | C|49998|0048488 DRAWING DATA=CPG1022-1 |96169| D| |D|0003 | C|49998|0049407 DRAWING DATA=CPG1022-1 |96169| D| |D|0004 | D|49998|0061828 DRAWING DATA=CPG1022-1 |96169| D| |D|0005 | B|49998|0017369 DRAWING DATA=CPG1022-1 |96169| D| |D|0006 | D|49998|0024738 DRAWING DATA=CPG1022-1 |96169| D| |D|0007 | B|49998|0020905 DRAWING DATA=CPG1022-1 |96169| D| |D|0008 | D|49998|0019097 DRAWING DATA=CPG1022-1 |96169| D| |D|0009 | C|49998|0017763 DRAWING DATA=CPG1022-1 |96169| D| |D|0010 | D|49998|0055696 DRAWING DATA=CPG1022-1 |96169| D| |D|0011 | B|49998|0015906 DOCUMENT REF DATA=FED-STD-H28 | | |B |190424|A| | | DOCUMENT REF DATA=FED-STD-H28 |0020| |B |941221|A| |01| DOCUMENT REF DATA=ANSI/ASQ Z1.4 | | | |080101|A| | | DOCUMENT REF DATA=QQ-N-286 | | |G |001207|A| | | DOCUMENT REF DATA=MIL-STD-792 | | |F |060519|A| | | DOCUMENT REF DATA=MIL-DTL-915 |0081| | |020822|A| |02| DOCUMENT REF DATA=MIL-STD-2035 | | |A |950515|A| | | DOCUMENT REF DATA=MIL-STD-2132 | | |D |080310|A| |01| DOCUMENT REF DATA=ISO_9001 | | | |081115|A| | | DOCUMENT REF DATA=ISO10012 | | | |030415|A| | | DOCUMENT REF DATA=ISO/IEC 17025 | | | |050515|A| | | DOCUMENT REF DATA=MIL-I-45208 | | |A |810724|A| 1| | DOCUMENT REF DATA=MIL-STD-45662 | | |A |880801|A| | | DOCUMENT REF DATA=A-A-59004 | | |B |081118|A| | | DOCUMENT REF DATA=ANSI/NCSL Z540.3 | | | |130326|A| | | DOCUMENT REF DATA=0900-LP-001-7000 | | | |810101|C| |01| DOCUMENT REF DATA=S9074-AQ-GIB-010/248 | | |1 |191112|A| | | DOCUMENT REF DATA=T9074-AS-GIB-010/271 | | |1 |140911|A| | | DOCUMENT REF DATA=S9074-AR-GIB-010A/278 (CHG A) | | | |130214|A| | | 3.

REQUIREMENTS 3.1 Manufacture and Design - The item furnished under this contract/purchase order must meet the

requirements as specified in CPG 1022, except as amplified or modified herein. CPG 1022 ordering data information is provided below.

  • (a) Penetrator, Electrical, Trident Submarine; CPG 1022.
  • (b) ;Hull Penetrator Assembly for 18 Twisted Pair Cables, CPG 1022/1;
  • (c) Level of preservation, packaging, packing, and marking must be as specified elsewhere in the contract/purchase order.
  • (d) Length of outboard cable - ;Minimum of 100 Feet per MIL-DTL-915/81 (Type 1PR-A20E); 3.2 First Article Approval (Government Testing) - First Article Test (FAT) and approval is required. 3.3 ;The FAT sample(s) must not be delivered against the contract quantity.; 3.4 ;Paragraphs 4.1 and 4.1.1 of CPG 1022 do not apply.; 3.5 Material for Parts Requiring Certification - Quantitative chemical and mechanical analysis is required for the parts listed below unless specifically stated otherwise: Part - ;Body, Hull Penetrator CPG 1022/1-001 S1; Body Cap, Hull Penetrator CPG 1022/1-001 S2; Washer CPG 1022/1-006 and Nut CPG 1022/1-005; Material - ;QQ-N-286, Form 2, Annealed and Age Hardened or QQ-N-286, Form 7, Annealed and Age Hardened; 3.6 Testing Certification - Certifications are required for the following tests on the items listed below. Additional testing on other piece parts (if any) per applicable drawings and specifications is still required, but certifications are only required as listed below. Test - Non-Destructive Tests Item - ;Weld Repair and/or Production Weld (as applicable); Performance - Per applicable fabrication specification Acceptance - Per applicable fabrication specification Attribute - Time Temperature plots and certified calibration records of furnace temperature measuring devices Item - ;Body, Hull Penetrator CPG 1022/1-001 S1; Body Cap, Hull Penetrator CPG 1022/1-001 S2; Washer CPG 1022/1-006 and Nut CPG 1022/1-005; Performance - ;When required by CPG 1022, paragraph 3.3.1.2; Test - Quality Conformance/Compliance Inspection Item - ;Each Hull Penetrator Assembly; Performance - ;CPG 1022 paragraph 4.5; Acceptance - ;CPG 1022 paragraph 4.5, The hold time for the Hydrostatic Pressure Test Step 9 must be 2 hours for Quality Conformance Inspection Tests.; Attribute - Annealing and Age Hardening Item - ;Body, Hull Penetrator CPG 1022/1-001 S1; Body Cap, Hull Penetrator CPG 1022/1-001 S2; Washer CPG 1022/1-006 and Nut CPG 1022/1-005; Performance - QQ-N-286 Test - ;Dye Penetrant Inspection; Item - ;Body, Hull Penetrator CPG 1022/1-001 S1; Body Cap, Hull Penetrator CPG 1022/1-001 S2; Washer CPG 1022/1-006 and Nut CPG 1022/1-005; Performance - T9074-AS-GIB-010/271 Acceptance - MIL-STD-2035 Test - Ultrasonic Inspection on Starting Material Item - ;All Items requiring certification made from QQ-N-286 with a diameter or minimum distance between parallel surfaces of 4 inches or greater of the starting material, or when required by a drawing or specification invoked elsewhere in this contract; Performance - T9074-AS-GIB-010/271 or MIL-STD-2132, and QQ-N-286 Acceptance - QQ-N-286 3.7 The pressure tolerance must be as specified in the assembly drawing, detail drawing, design specification or elsewhere in this contract. Where pressure tolerances are not provided by drawings, specifications or specified elsewhere in this contract, the following must be used: For pressure tests below 100 PSIG, the pressure tolerance must be +1 PSIG / -0 PSIG. For pressure tests at or above 100 PSIG up to and including 2500 PSIG, the pressure tolerance must be +2% / -0 PSIG rounded off to the nearest multiple of the smallest graduation on an analog test pressure gauge, not to exceed 50 PSIG. For pressure tests above 2500 PSIG, the pressure tolerance must be +2% / -0 PSIG, rounded off to the nearest multiple of the smallest graduation on an analog test pressure gauge, not to exceed 200 PSIG. The pressure test time tolerance must be as specified in the assembly drawing, detail drawing, design specification or elsewhere in this contract. Where pressure test time tolerances are not provided by drawings, specifications or specified elsewhere in this contract, the following must be used: For a test duration up to and including 1 hour, the tolerance must be +5 minutes / - 0 minutes. For a test duration of more than 1 hour up to and including 24 hours, the tolerance must be +30 minutes / - 0 minutes. For a test duration of more than 24 hours, the tolerance must be +60 minutes / - 0 minutes. 3.8 Thread Inspection