The response deadline has passed. Review the details for future reference or to track similar opportunities.
The Department of Veterans Affairs is seeking market research for a Dentsply Primescan Intraoral Scanner or equivalent for the Grand Junction VA Medical Center. The requirement includes a high-resolution 3-D scanner, image processing electronics, a laptop, and associated accessories. Key requirements include onsite installation and one day of training.
Provision of a CAD system for high-precision intraoral optical impressions, including hardware, software, and training.
Sources Sought Notice Sources Sought Notice Page 6 of 6 Sources Sought Notice = Required Field Sources Sought Notice Page 1 of 6 Sources Sought Notice Dentsply PrimeScan Intraoral Scanner (or equivalent) Disclaimer: This Request for Information (RFI) is issued solely for market research information and planning purposes and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. Responses to this notice are NOT offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI. Information Requested from Industry: In response to the Sources Sought, interested Contractors shall submit the following information and any Capabilities/Qualifications Statement to include but not limited to an overview of proposed solution(s) and a description of the product your company possesses in accordance with the Statement of Work draft / Salient Characteristics List. Responses to market research table questionnaire shall be submitted. If this information is not provided, then it will be assumed the entire requirement cannot be met. Description of Requirement: The Department of Veterans Affairs, Veterans Health Administration (VHA), Network Contracting (NCO
19) is conducting a market survey and is seeking potential sources for a Dentsply Primescan Intraoral Scanner (or equivalent) for the Grand Junction VA Medical Center. This Sources Sought Notice is issued for information and planning purposes only.
This is not a solicitation or a request for proposal and shall not be construed as an obligation or commitment by the Government. An award will not be made on any offers submitted in response to this notice, and it shall not be implied that the Government is committed to providing any solicitation or award following this notice. The Government will not pay for any information received in response to this request, nor will the Government compensate a respondent for any costs incurred in developing the information provided. Requirement Item: Primescan Intraoral Scanner (or equivalent) Item No. Part Number Item Description 1 6795491 Primescan Intraoral Scanner Required Salient Characteristic: The Intraoral scanner is a CAD system for high-precision intraoral optical impressions, including: High-resolution, heated oral scanner (3-D scanner) with removable reflective sleeve Integrated image processing Coupling box, including interfaces Scanner Holder The high-resolution 3-D intraoral scanner with control & image processing electronics Image acquisition: Image control inside scanner Image data transfer: USB 2.0 standard Specific equipment that is part of the intraoral scanner includes: The scanner, connection cables, and laptop, all to be covered under the maintenance program. Additional equipment/supplies to be included in this requirement: Disposable reflective sleeves Flex cart Onsite 1-Day Training Installation In response to this announcement, please provide the information requested below requested in this market research table questionnaire. If this information is not provided, then it will be assumed the entire requirement cannot be met: NAICS Code: Company Name: Address: UEI (Unique Entity ID) Number: Contact Name: Phone No.: Email: Business Size Information - Select all that applies: Small Business Emerging Small Business Small Disadvantaged Business Certified under Section 8(a) of the Small Business Act HUBZone Woman Owned Certified Service-Disabled Veteran Owned Small Veteran Owned Small Business Large Business FSS/GSA Contract Holder: Yes No FSS/GSA Contract Number: Effective Date/ Expiration Date: Proposed solution is listed and available on the above FSS/GSA Contract: Yes No Available
pricing structure of proposed solution
Pricing Model Please Indicate Availability Below: (Yes / No / NA) All on FSS Open Market only Mix of FSS & Open Market Firm-Fixed Price Other: (Please explain) Market Rearch
Questions: How long from receipt of order to delivery? Buy American Act RFO 52.225-1 and RFO 52.225-2 Buy American Certificate What percentage of the proposed product (including leases and rentals) is a: Domestic end product? _____________ (%) Foreign end product? _______________ (%) Country of Origin:
Get matched to contracts like this daily
Free AI-powered contract matching for your business.