Closed
Save

Anesthesia Testing Equipment

Veterans Affairs (VA)Sol: 36C25726Q0506
8(a)HUBZoneSDVOSBWOSB

This opportunity is closed

The response deadline has passed. Review the details for future reference or to track similar opportunities.

Quick Brief

The Department of Veterans Affairs is seeking to procure anesthesia testing equipment for the Healthcare Technology Management Department at the Thomas E Creek - Amarillo VA Healthcare System. The required equipment must be capable of testing various models of ventilators and other medical devices, ensuring compliance with applicable standards and specifications. Interested vendors are encouraged to submit their business information and qualifications for potential set-asides.

Generated 30d ago

Contract Details

Awarded Amount
Not specified
Similar contracts award $259$25K (median $5K, 45,761 awards)
NAICS Codes
Set-Asides
8(a), HUBZone, SDVOSB, WOSB

Agency & Contact

Contracting Organization

Agency
VETERANS AFFAIRS, DEPARTMENT OF

Point of Contact

John A. Smith
Contracting Officer
(202) 555-0100

Key Dates

Published1mo ago
May 4, 2026
Response Due Date1mo ago
May 4, 202610:00 AM
Response Due1mo ago
May 4, 2026
Became Award Notice1mo ago
May 4, 2026
Tracked
Last Updated1mo ago
May 5, 2026

Description

Page 4 of 4 Page 4 of 4 Page 1 of Page 1 of This market research notice is being conducted by Network

Contracting Office (NCO) 17- VA South Texas (VASTHCS) facilities. The Thomas E Creek - Amarillo VA Healthcare System is seeking to purchase equipment for the Healthcare Technology Management (HTM) Department to assist with Preventive Maintenance (PM) and troubleshooting. The equipment being requested must help the HTM Department test virtually all models of ventilators: adult, pediatric, anesthesia, neonatal, and high frequency. Description of work: The equipment must test a variety of other medical equipment such as anesthesia gas delivery machines [measure concentration in percentage for Desflurane (Suprane), Sevoflurane, Isoflurane (Forane) and Halothane], air-oxygen blenders, medical insufflators, oxygen concentrators, CPAPs, and other devices with pneumatic gas flows. REQUESTED EQUIPMENT

A. NAME/DESCRIPTION OF EQUIPMENT- TSI Certifier Plus Full Kit MANUFACTURER- BC Group MODEL- 4080-F (4089+4081+4073+1 Lung) Quantity- 1 Unit- KIT

B. NAME/DESCRIPTION OF EQUIPMENT- TSI Certifier Plus Low Flow Kit MANUFACTURER- BC Group MODEL- 4082 Quantity- 1 Unit- KIT

C. NAME/DESCRIPTION OF EQUIPMENT- Riken Anesthetic Agent Analyzer MANUFACTURER- BC Group MODEL- FL-8000P Quantity- 2 Unit- EACH

D. NAME/DESCRIPTION OF EQUIPMENT- Anesthetic Agent Analyzer (BT, CO2, AutoID, Mix) MANUFACTURER- BC Group MODEL- AA-8100 Quantity- 2 Unit- EACH Contract service shall ensure that the equipment functions in conformance with the latest published edition of the applicable standards, such as: National Fire Protection Association (NFPA-99); Underwriters Laboratories / Occupational Safety and Health Administration (UL OSHA); Dept of Veterans Affairs (VA); Center for Devices and Radiological Health (CDRH), etc. and the Manufacturers Performance standards/specifications as used when the equipment was originally procured and that any upgrades/updates will meet the standards/specifications. Responses shall include: Business Name Business Address

Get matched to contracts like this daily

Free AI-powered contract matching for your business.