The agency is researching potential vendors before issuing a formal solicitation. Responding shows your capabilities and can influence the final RFP.
The Department of Justice is seeking contractors to supply and deliver air-cooled chillers and centrifugal pumps for the Federal Correctional Complex in Oakdale, LA. Key requirements include providing new equipment that meets federal, state, and local codes, as well as manufacturer-certified start-up services after installation by FCC Oakdale HVAC staff.
Get your fit score, win probability, and required capabilities.
The work involves supplying air-cooled chillers and centrifugal pumps, along with start-up services, to the FCC Oakdale.
This listing does not include downloadable attachments. The solicitation details may be in the description below.
Verify on SAM.govFCC Oakdale – B&F PROJECT 26Z5AW6 Replace Chillers and Pumps – Supply Only
This is a Sources Sought Notice issued for market research information and planning purposes only. It does not constitute a solicitation and responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Participation is voluntary and a response is not required to compete in any potential future solicitation. However, responses to this notice may influence the Government’s development of a future requirement and future acquisition strategy (e.g. set-aside, full and open competition). Respondents will not be notified of the results of this market research effort. No reimbursement will be made for any costs associated with responding to this Sources Sought Notice. 1. Agency and Location Federal Bureau of Prisons (FBOP) Federal Correctional Complex (FCC) Oakdale 1507 East Whatley Road, Oakdale, LA 71463 2. Purpose FCC Oakdale seeks to identify capable contractors able to furnish and deliver air‑cooled chillers, centrifugal pumps, and provide manufacturer‑certified start‑up services. Installation will be performed by FCC Oakdale HVAC staff. 3. Required Equipment and Salient Characteristics All equipment must be new, meet all Federal, State, and local codes, and conform to the salient characteristics below. Information is taken directly from the specification sheet.
A. Chillers 1. Trane Sintesis Air‑Cooled Chiller – Model RTAF115E (Brand Name or Equal) Quantity: Nine (9) Salient Characteristics: • 115 nominal tons • High‑efficiency unit • Voltage: 460V / 60Hz / 3‑phase • Refrigerant: R‑513A • UL listed • ASME pressure vessel code compliant • Meets ASHRAE 90.1 (all versions up to
2016) 2. Trane CGAM Air‑Cooled Scroll Chiller (Brand Name or Equal) Quantity: Two (2) Salient Characteristics: • 80 nominal tons • High‑efficiency unit • Voltage: 460V / 60Hz / 3‑phase • Refrigerant: R‑454B • UL listed • ASME pressure vessel code compliant • Meets ASHRAE 90.1 (all versions up to
2016)
B. Centrifugal Pumps (All pumps Bell & Gossett Series 1510 or equal.) 1. Pump Set A Quantity: Ten (10) Salient Characteristics: • 8" impeller • 150 GPM • 100 ft head • 5 HP • 230–460V • 2½" discharge • 3" suction 2. Pump Set B Quantity: Nine (9) Salient Characteristics: • 8" impeller • 150 GPM • 100 ft head • 5 HP • 230–460V • 2" discharge • 2½" suction